This is to facilitate easiest searches of for example fundamental small molecules or large molecules presentations; making chemistry knowledge easily findable, accessible and increasing beginners knowledge of such chromatography method development.
Curious about your research experiences. Ideally this is for ESI-QTOF electrospray ionisation. This will differ based on type of columns and equilibration as per dimensions, flow rate and size of...
09 October 2017 5,453 6 View
08 September 2017 8,659 6 View
For me cite them right website for referencing got lab reports done easy with references. Learned web of science makes results so narrow and easy to find. Google scholar let me find cited articles...
08 September 2017 5,953 2 View
the water layer would have formed using 85%. Is the same amount of water layer formed by each acetonitrile %.what I am asking is for 97% if I equilibrat for 2 hrs then can I equilibrate for 30 to...
08 September 2017 7,296 11 View
,Tried 3% water layer but equilibration time is time consuming. Analyte had a curved out looking shape such as an upside boat that continued for 2minutes to reach the baseline. steep then smooth...
08 September 2017 4,633 9 View
I read in Mass spec literature that buffer combinations are attempted. Are they only for gradient elution. Does this need mass spec to ionise the buffered solvent effectively. Will this cause the...
08 September 2017 617 4 View
LogP
08 September 2017 720 5 View
08 September 2017 7,121 2 View
This situation can be applied to 2D chromatography. If there is a T-piece can two To void volume markers be used to measure that volume for sample to reach the detector. Some research applies...
08 September 2017 9,947 5 View
Just wondering about their expense to make. Does liquid propulsion cause excess interference in IR?. A multifunctional HPLC that checks for impurities would be more valuable. Does the liquid...
08 September 2017 7,457 5 View
How to calculate the RMSD values for a MD simulation using MOE?
07 August 2021 0 0 View
When I tried to energy minimization my system, I got fatal error as below. Fatal error: Atomtype opls_116 not found Although I've already added this line: ; include water #include "oplsaa.ff/spc.itp" to [molecultype] directive in my topology.
16 June 2021 0 0 View
effect of double bond on the flexibility of polymers
07 April 2021 0 0 View
I am writing to request some information for making polymer color flakes. I would appreciate the help.
17 March 2021 0 0 View
Hiiiii everyone! I have an enquiry on statistical analysis. I was looking for many forum and it's still cannot solve my problem. I want to compare means of two groups of data but only with two...
03 March 2021 8,796 3 View
Hello, If i am doing a buffer exchange for an antibody of 1mg/mL, does the elution lose protein in the process of buffer exchange? For example, if i flow through 500 uL of 1mg/mL sample, and...
03 March 2021 6,299 3 View