I am trying to simulate the membrane patch of 5 lipid mixture obtained from the CHARMM-GUI (I edited the output README file as 1 to 20 for getting a total of 20 ns production run, and all simulations are done with single precision gromacs 5.0.4). With the default parameters, when I analyzed the last 5 ns trajectory , I found vary strange results for pressure and density as average pressure was found 1.6 bar and the average density of the water was found 1049 kg/m3.
So, do I need more longer simulation for the convergence of pressure and density to the reference values or I am doing something wrong.
mdp parameter file
integrator = md
dt = 0.002
nsteps = 500000
nstlog = 1000
nstxout = 5000
nstvout = 5000
nstfout = 5000
nstcalcenergy = 100
nstenergy = 1000
;
cutoff-scheme = Verlet
nstlist = 20
rlist = 1.2
coulombtype = pme
rcoulomb = 1.2
vdwtype = Cut-off
vdw-modifier = Force-switch
rvdw_switch = 1.0
rvdw = 1.2
;
tcoupl = Nose-Hoover
tc_grps = NPROT SOL_ION
tau_t = 1.0 1.0
ref_t = 310.15 310.15
;
pcoupl = Parrinello-Rahman
pcoupltype = semiisotropic
tau_p = 5.0 5.0
compressibility = 4.5e-5 4.5e-5
ref_p = 1.0 1.0
;
constraints = h-bonds
constraint_algorithm = LINCS
continuation = yes
;
nstcomm = 100
comm_mode = linear
comm_grps = NPROT SOL_ION
;
refcoord_scaling = com