It may be assumed that Current is 2.5 A and electrode plate have length : 10cm, width 6 cm and breadth 1 cm.
Need to calculate current density for electrocoagulation.
Pratibha Gautam
The current density is : j [A.cm-2] = I [A] / S [cm2]
Since you know the surface of your plate, the calculus will be pretty straight forward.
Best regards,
Marie B.
I am not able to get similar results while repeating same experiments for treating leachate through electrocoagulation. Results are not even comparable. What can be the reason.
01 January 1970 8,361 11 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I am experimenting with cancer and non-cancer cells in a 12-well plate for 4 days with a seeding density 1*10^4/well, however, I noticed that the control group growth rate slows down on D3. Should...
07 August 2024 2,283 2 View
Hi, I have a question about normalizing the MTT OD values for doing the statistical analysis. So, if we have 3 different plates and we call them 3 different replicates, so, first we would...
07 August 2024 8,106 4 View
I have been performing short phagocytosis experiments using 96-round bottom, tissue culture treated, well plates (Falcon, 353077). I culture the cells with the phagocytic cargo for 2-4hrs, wash...
04 August 2024 5,228 4 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
In my study, I intend to infect PBMCs with SARS-CoV-2. After that, I will analyze NK cells by flow cytometry to see if their phenotype changes or if they show degranulation. After the infection, I...
01 August 2024 4,403 4 View
Dear researchers, Today, we found this object in one of the wells of a 96wp culture plate. The plate contained MEC-1 cells and GelTrex. I am quite curious what this is (because it's not cells). Do...
01 August 2024 2,250 2 View
Does anybody know of entomological Journals without page charges that would publish an extensive checklist (Hong Kong Aculeates wasps) covering 350 species (of which more than half are new to Hong...
01 August 2024 6,134 2 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View