Hi everybody
I have set up a model in comsol 5.2 which consists of a capillary. On the outlet of the capillary, I want to impose a zero gradient for all variables except pressure? how can I do this?
Thanks in advance
Hamid
Why have you not use free surface or tension surface with zero magnitude?
Hi
I think the model has nothing to do with a free surface flow or even surface tension. it is a single phase laminar flow through a channel.
PhD University Selection
31 December 2015 6,828 3 View
When I conducted the degassing experiment using decompression under anaerobic condition(and I used ferrous based chelating agent), the oxidized ferric were observerd. So, could you tell me the...
03 March 2021 4,892 5 View
We use reactive sputtering process to make aluminum nitride film, and want to make c-axis aluminum nitride film on a silicon substrate, but the crystal orientation cannot be seen with...
03 March 2021 7,975 3 View
Hi, im trying to make a projection in a 3d comsol model. I have a non uniforme chanel and my intention is to get the average tempreture in the y-z cross section and se the average tempreture...
02 March 2021 4,624 4 View
We found tests to determine cardiovascular risk taking into account lipid profile, blood pressure, age, history of diabetes, other laboratories. But when weight is involved, there is a paradox. I...
02 March 2021 6,036 1 View
Hello, I have a mechanism where air rises due to convective flows. In this simulation, nothing is driving the air except this. I understand that the Boussinesq approximation only works for small...
02 March 2021 4,910 3 View
How to do Piezoelectric coupling in ANSYS-APDL or COMSOL between tapered substrate and rectangular piezoelectric patch? Piezoelectric coupling between the rectangular substrate and rectangular...
02 March 2021 9,833 3 View
(This statement is from wikipedia, BTW). What is so special about metallic bond that is limiting high-P low-T state of a matter (as long as individual atoms exist, not white dwarf of neutron star...
02 March 2021 3,309 2 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
Hi, I am trying to figure out which test would be most appropriate to run for the following question: Is there a difference in task blood pressure between smokers and non-smokers? There are two...
01 March 2021 8,235 2 View
How do I do energy minimization in lammps with NVT ensemble ? I am using the following command and it does not seem to work. It stops at extremely high energy and gives me the error zero search...
01 March 2021 2,294 3 View