After working with phenol what is the best way to clean the glassware contaminated with Phenol? is neutralizing them with 1M NaOH a good idea?
Probably 1M NaOH is enough to clean the glassware. KOH is good also.
Phenol is reasonably soluble in water. I personally would just wash it with water to remove any residual phenol and then dispose of the wash in your aqueous waste container. From there, clean as you normally would.
I've tested a variety of reagents for the synthesis of a compound and found one that has never been used before and yields a good product. after my experiments i did some research and came across...
08 September 2018 9,071 3 View
sorptivity is defined as the capacity of soil to absorb or desorb water by capillarity. but what does higher sorptivity mean? does it mean the part of infiltartion that depends on capillarity...
06 July 2018 1,715 5 View
Hi everyone I have a question about showing significant difference between treatments in a table using letters. I have 6 total treatments (one control and 5 treatments) like this : Control...
06 July 2018 5,374 6 View
I've seen that the saturated hydraulic conductivity is calculated Darcy’s law and field saturated conductivity is calculated using philip's equation. what is the exact difference between these two...
05 June 2018 2,997 1 View
Hello everyone! In my experiments i have 5 different treatments plus a control, each treatment was carried out 3 times and i wanted to know can i use one way ANOVA to analyze the results? if not...
05 June 2018 7,370 3 View
hi everyone i have some diethyl ether which seems to have some yellow colored impurities, i want to distill it, knowing that the boiling point is ~ 34 °C, it doesn't seem to need much heating but...
05 June 2018 2,043 4 View
what's the best method for synthesis of p-Toluenesulfonic acid doped polyaniline? can anyone suggest some good references? i have found some articles, but they are not very clear. also is...
31 December 2017 4,808 3 View
how is soil pH determined? I see that in some articles a 1:1 ratio of soil to water is used for determination of pH, and in some papers a 1:5 soil to water ratio is used, what's the difference and...
10 November 2017 2,180 16 View
I want to use cellulose in a synthesis but looking through manufacturer's websites to buy it , all i can find is Cellulose microcrystalline . as far as i know microcrystalline cellulose is...
09 October 2017 9,928 5 View
I vacuum distilled my aniline a while ago but now it has a slight yellow tint to it, i want to use it for polymerization. is it still usable? i would distill it again, but my vacuum system needs...
08 September 2017 9,010 11 View
Approximate concentrations are require in compared with the WHO permissible limts
11 August 2024 2,723 1 View
Hey there, As a synthetic chemist delving into theoretical calculations for my imidazolium-based organic molecules, I would greatly appreciate any guidance on the appropriate input instructions...
09 August 2024 5,444 7 View
Hello everyone! I observed in my culture (htert-RPE1 cells) an orange- red particle at the bottom of the dish. It is visible to the naked eye as a very very small red dot. Could it be a...
09 August 2024 2,824 3 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
Hello What should be done to separate and identify organic acids in HPC when their RetTime is the same?Like oxalic acid with Propanoic Acid.or acids that have a very close RetTime.
07 August 2024 8,782 3 View
Recently, we observed that 99% of the sequences in our RNA-seq data corresponded to the E. coli genome. Despite multiple DNAse treatments after RNA extraction and ribosomal depletion, we were...
06 August 2024 807 3 View
Hi everyone I need a file with a dirty and clean potato image
04 August 2024 7,199 4 View
I used humic acid at 0.044 g/kg soil in my pot experiment. But finally, I have to recommend kg/ha. Each pot's soil weight was 11 kg. What is the solution?
02 August 2024 7,186 6 View
The module of the CAD detector is corona Veo. It has been idle for a long time. And it was not well maintained before idle. I have replaced the gas filters and flushed the system with a 50/50...
01 August 2024 7,805 0 View
Hi everyone, I'd like to better separate two close peaks coming from a bioconversion sample, I'm currently using a C18 KromaPhase 4,6mm Ø.I. SCHARLAU, particle size (µm): 10, pore size (Å): 100,...
30 July 2024 435 3 View