Hello everybody,
I have a qestion about the implementation of the XRF to determine the thickness of the NiP -Cr coating on a stainless steel (1.4305). According to the TDS of the base Material, it contains both Ni and Cr. I made multiple measurements in one spot and results were ranging from 7 to 10 µm for a NiP layer. The measurement was done for a given base material, nevertheless it is difficult to guarantee that on this particular spot that I measure, the composition of a steel will correspond to the information from the TDS. I read in the literature, that it is impossible to perform an accurate measurement when the composition of the base material and a coating are overlaping. Does anyone have an experience in this topic? Or can anyone recommend another technique to establish the thickness of the coating?
Many thanks in advance.