A compact layer of TiO2 is to be deposited on top.
If you have access to plasma cleaning device - it might be used also to etch the surface, and in some cases to reduce the roughness, also in FTO.
However, if the surface roughness is critical for you, you might use other TCOs (ITO, AZO, etc.) instead of FTO.
David,
I checked (air) plasma cleaning. Had almost no difference. After 30 minutes the roughness was reduced by about 2 nm (from~38 nm to ~36 nm). Do you have any specific guidelines for the plasma?
Dear all researchers, I would appreciate if anyone here can assist me to find a survey instrument related to customer churn behaviors from previous study? I couldn't find it. Thanks.
19 May 2024 1,184 0 View
How can isolate C2C12 myotube efficiently from C2C12 myoblast?
18 April 2024 6,123 0 View
1. When using the input shaper, it is necessary to design the natural frequency and damping ratio. How to solve this natural frequency and damping ratio for the time-varying robot dynamics...
10 April 2024 378 0 View
In the actual scenario of federated learning, the problem of heterogeneity is an inevitable challenge, so what can we do to alleviate the challenges caused by these heterogeneities?
19 March 2024 7,047 2 View
I have encountered an error to measure the light intensity of my laser source (650nm) (see image attached). The serial plot remains constant even i have changed the intensity of my light source, I...
06 January 2024 4,725 3 View
Specifically, I would like to determine the concentration of Marinobacter hydrocarbonoclasticus. Just like a UV-Vis, I will be using a GL55 photoresistor (as shown in the image attached) to...
20 November 2023 7,905 2 View
Hello, I would like to script the creation and assignment of a reference point to a geometry set in abaqus. In the .jnl file the code is:...
14 November 2023 662 2 View
I designed an mzi structure where the input is complete, but the output changes badly at the end of the coupling zone.How do I need to change the structure?
26 October 2023 537 0 View
I am a master student, can any expert suggest is the model suitable for my level or this is more advancing for PhD level? The proposed title for this research is: Investigating the Drivers of...
10 October 2023 8,366 1 View
I am planning a retrospective chart review study using data abstraction form. My questions are: 1) How many number of cases/percentage of cases to be selected for inter-rater reliability...
14 September 2023 7,448 0 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
I did PR spin coating on trench structure. I used AZ P4620 PR and the thickness or PR is around 11um. The substrate is Si. And my trench structure depth is 141um(negative way). Even though I...
08 August 2024 2,298 0 View
I have been getting a low plasma and no coating while doing rf sputtering of copper doped ZnS using a power of 140 watts and at pressure of 6.5x10-3 Mb.
07 August 2024 4,526 4 View
I want to know more about Magnetite deposits.
06 August 2024 1,066 0 View
For example, I perform passivation process before electropolymerization of Py for adhesion to titanium surface. Is a similar or different procedure required for ITO? If necessary, I would be glad...
06 August 2024 3,176 0 View
Global ‘Weather’ has stopped, as ‘aqua thermionic instituted by the ‘Global thermo atmospherics has instituted global thermodynamics of 120º C + and thus all waters are, or have boiled into a...
06 August 2024 8,716 0 View
How can I measure the thickness of thin film by Uv-Vis?
06 August 2024 7,810 3 View
Why is TLC not a form of partition chromatography and paper chromatography not a form of absorption chromatography?
03 August 2024 7,035 3 View
I fabricated Ti3C2Tx using concentrated HF 40%, I plot an XRD as attached image below.. please let to know if I obtained it or not.
02 August 2024 6,789 4 View