Fluorescence polarization
Should be possible, if the peptide is the fluorescent moiety. We have used sfGFP-peptide fusions to measure the affinity of Armadillo repeat proteins of different length by fluorescence polymersiation
http://www.bioc.uzh.ch/plueckthun/pdf/APpub0391.pdf
Dear Deep,
The answer is yes.The paper that provided as a link by Annemarie. It is quite interested and useful.
Structure and Energetic Contributions of a Designed Modular Peptide-Binding Protein with Picomolar Affinity
Simon Hansen, Dirk Tremmel, Chaithanya Madhurantakam,† Christian Reichen,‡ Peer R. E. Mittl,* and Andreas Plückthun*
J. Am. Chem. Soc. 2016, 138, 3526−3532
Find in attachment, Technical Resource Guide FOURTH EDITION
Fluorescence Polarization
Find in attachment, THEMATIC REVIEW Fluorescence Polarization: Analysis
of Carbohydrate±Protein Interaction
Kazuaki Kakehi,1 Yasuo Oda, and Mitsuhiro Kinoshita
Faculty of Pharmaceutical Sciences, Kinki University,
Kowakae 3-4-1, Higashi-Osaka 577, Japan
Analytical Biochemistry 297, 111±116 (2001)
doi:10.1006/abio.2001.5309, available online at http://www.idealibrary.com on
Find in attachment, a paper on: Peptids that mimic glycosaminoglycans:
high-a¤nity ligands for a hyaluronan binding domain
Michael R. Ziebell a;b; 1, Zhan-Gong Zhao b, Bai Luo c, Yi Luo b, Eva A. Turley d,
Glenn D. Prestwich
Chemistry & Biology 8 (2001) 1081^1094
I have three outputs, each with a different unit. I am searching for an error estimator with the help of which I can select the most suitable Neural Network configuration. I will have to compute...
26 January 2021 254 5 View
I have a dataset with 19 training points and 6 testing points. At first I defined the rules for 19 training sets and then tried making predictions for the rest of 6 points. But I got all constant...
06 January 2021 3,772 5 View
I am working on developing a predictive drive cycle for a specific city. I have gathered driving characteristics parameters for my target city. I have obtained similar data from previous research...
21 October 2020 6,663 8 View
I wish to estimate the expression of two types of markers by immunohistochemistry in the biopsy specimens of a particular type of cancer, and correlate their expressions with clinical parameters...
20 September 2020 9,662 6 View
I can use two/three electrode set up for liquid junction quantum dot sensitized solar cell.
15 August 2020 1,721 1 View
Is carbon element is present in concrete EDS, if yes how??
19 July 2020 5,248 8 View
Respected Scientists and Researchers, I am completely new to the field of computational chemistry. I am trying to run GAMESS by taking help of some tutorial videos available on internet. However...
11 June 2020 5,094 1 View
I am sorry if this is a simple question. I am trying to conduct a GWR for hedonic analysis of hotel room rates. For OLS I have conducted analysis including different room types (e.g. double,...
16 April 2020 7,062 3 View
I am trying to implement a model predictive controller to control my soft robot. Right now, the robot is being controlled in an open loop. I have written python code for the MPC but the codes are...
05 March 2020 835 3 View
Why is only femto second laser used. How is it related to terahertz generation?
08 November 2019 6,360 2 View
Hi all, I am validating a polyclonal antibody raised against human ANT4, through WB and ICC. In most of my controls, the antibody shows very little off-target binding, but when I pre-incubate the...
03 March 2021 5,999 3 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
I am a research scholar working on heavy metal stress on plants. I will be doing biochemical characterisation( protein, carbohydrate, proline, antioxidant enzymes and many more assays) at interval...
01 March 2021 6,999 3 View
Hi all, I have been working on the quantification of chitin in insect samples and feed for a while but I can notice that the quantification methods (e.g. exposure to HCl, NaOH, and weighing sample...
01 March 2021 1,843 2 View
I am growing the cells on coverslips and transfecting the fluorescent tagged protein directly on them. Then i want to observe these cells under confocal microscope. Currently i am just using...
01 March 2021 6,142 3 View
Is there any reason for decrease in fluorescence emission intensity of HSA,BSA when increase the concentration ?
28 February 2021 3,653 4 View
Hi, all! I need to determine if my treatment causes membrane damage in bacteria (S. aureus and E. cloacae), but I cannot use a fluorescent probe such as PI and similar ones because my compound is...
24 February 2021 2,006 2 View
23 February 2021 4,014 3 View
I am working on synthesizing and then purifying peptides using the SPPS system. After purification of the peptide, the peptide powder is obtained using a freeze dryer. When measuring the powder,...
22 February 2021 10,099 5 View
I have synthesized the peptide using Fmoc based solid phase peptide synthesis. Also I have cleaved the peptide from the resin and lyophilized it, but later realized that, I forgot to deprotect the...
21 February 2021 4,537 3 View