Because in my case, for 10 storied RC frame, drift values are coming maximum at the same node for every increase of intensity.
It may be at any point. It is required to be check.
Genome-wide association study (GWAS) Continuous traits: eg. Height Discrete traits: eg. Eye color
28 July 2024 286 0 View
Though much literature suggests fitting a Voigt profile on a LIBS peak, is it also possible to fit a Gaussian profile on the LIBS peak? I have 204 spectra files, and I am building a pipeline for...
23 July 2024 6,127 1 View
After incubation of the TG1 cells with the helper phage, I spun down the culture and precipitated the supernatant with PEG/NaCl. After this, I spun it down again and resupended the pellet in PBS....
21 June 2024 6,260 2 View
I have 17 different steel samples, in which i identified a peak of Ti 441.492. But , if you look closely at photo, while some some peak are at 441.492 , some are at the slight offset. eg 441.490...
10 June 2024 8,934 2 View
Respected Members , I have a 17 different steel sample references , with varying concentration for Minor Elements being Mo , Ni , Mn ,Si , Cr etc , i am trying to build a calibration curve with...
10 June 2024 993 0 View
Hello Everyone ! I have a samples a satinless steel , I performed the LIBS Measurement with hLIBS (SciAps Z-300). Total of 12 measurements on different locations were done on the same sample...
09 May 2024 7,959 6 View
Some journals seems to be fake..cloned
07 May 2024 3,623 1 View
Dear Colleagues, Does anyone know about Universities that are offering (a) Ph.D. by prior publication (b) Ph.D. by portfolio? I have two publications viz."Regression Testing in Era of Internet of...
09 April 2024 2,123 1 View
Relative molar composition of 1.0 TEOS : 0.2 CTACl : 0.0026–0.017 LS277 dye : 10.4 TEA : 142 H2O was used.
04 April 2024 6,770 1 View
As heat exchangers in the heat exchanger networks get fouled, the utility in the furnace has to increased to compensate the losses. Apart from it, the pumping cost must be increasing as deposited...
04 February 2024 531 3 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
In hirshfeld surface calculation i did not find any red spot in hirshfeld surface, is it ok for research article to write?
28 July 2024 2,988 0 View
I have used 30 years of daily data, but the model is not able to optimize, getting just 0.57 in NSE and R2. when I reduced the data to 20 years in daily time frame I got 0.73 in NSE, R2 for both...
22 July 2024 669 0 View
Dear Members of ResearchGate, I hope you are doing well. I have been retrofitting using the ASCE 41 2017 standard. In it, I have two basic doubts. 1. The target displacement as per clause...
13 June 2024 2,773 0 View
how to observe the hysteretic energy consumption for a parrticular frame element
12 June 2024 3,426 1 View
Hi, I am calculating the periods of a steel building modeled as a 3D moment frame. Is there any script to display the shape of vibrating of the model in opensees?
12 June 2024 8,065 1 View
Hi, I am running an opensees model of a 2-bay 1-storey frame with settlement at the mid-support. I wanted to add an additional frame element as a bracing to the analyzed frame after it sustains...
08 June 2024 4,132 0 View
I need to calculate dG MM/GBSA energy through the MD simulation trajectories. From RMSD values I selected last 400 frames from MD trajectories. I ran thermal_mmgbsa.py script, but it calculates dG...
22 May 2024 10,076 5 View
A spinor field in classical differential geometry is defined as a section of a spinor bundle, which is by definition the associated bundle constructed from the spinor representation and the...
14 May 2024 400 0 View
I'm performing an antibody phage display with a VHH library and I consistently get frameshift mutants (mainly frame +2) after biopanning. I'm using TG-1 cells for amplification of phagemids and...
14 May 2024 412 2 View