How to tailor drug release with PCL and PLGA blend upto 2 weeks or 3 weeks? We are having 20 % release in three weeks & we want to make it 100 % in two or three weeks? If somebody had any idea or worked with the same blend?
Dear Haroon
Vary the blend ratio might help, see also publication below.
Fabrication and Characterization of Poly(lactic acid)/Poly( ε -caprolactone) Blend Electrospun Fibers Loaded with Amoxicillin for Tunable Delivering
DOI: 10.1166/jnn.2015.9726
other starting points could be to vary fiber diameter and/or spin the fiber itself more porous by inducing phase separations.
Regards
Marc
Further to the above answer, the degradation rate of PLGA is based on the ration of lactic and glycolic acids. Please see the following publication:
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
doi: 10.3390/polym3031377
Kind Regards,
Chris
These fungal slides are isolated from cultured Bread mold on PDA media and smear is treated with Lacto phenol Blue dye ..
13 July 2024 9,701 1 View
Respected All Research Members. Actulaay I faced the problem while analysis the EIS Data as i got the value of Z" negative. What should be the possible reason for this. Thank you in advance
03 July 2024 4,336 3 View
I have to join tungsten wire to metallic plate with that adhesive and entire assembly has to be heated upto 600C in ultra high vacuum. I know about zirconia paste but it is not readily available...
18 June 2024 3,092 3 View
fungal inoculum treated with lacto phenol blue and observed under microscope anyone help me to identify and share some information regarding this fungal slide
07 June 2024 9,647 3 View
I am implementing an enhanced objective function for RPL. Control messages and data packets of UDP applications are being transmitted. Now the question is that if any data packet which is being...
02 June 2024 3,418 2 View
FeCrAlloy® foils are commonly used for fabricating metallic monoliths. However, their lack of specific surface area/roughness (pores) hinders catalyst adhesion during the coating process. Several...
22 May 2024 8,462 1 View
Explain your ideas
07 May 2024 4,553 2 View
I have selected the waste management topic for my Thesis Project, where I selected the bio-medical waste management, now my supervisor asked me to show him the importance of bio-medical waste...
12 April 2024 1,734 2 View
Greetings, I am Mamun. I just want to know that if I use 7% margin of error than will it cause any problem in future analysis? I am using stratified sampling technique, for this if i take 7%...
06 April 2024 2,344 6 View
having weight of filter paper initial and final, salt concentration, water percentage, temperature. want total and osmotic suction analysis
21 March 2024 8,669 0 View
kindly reply me. Thanking you in advance.
05 August 2024 7,727 4 View
I am currently working on a project involving liposomes and need to determine the maximum volume of siRNA that can be added to a 2.5 mL liposome solution with a total lipid concentration of 10...
30 July 2024 6,420 1 View
How can the rubber fibres produced by the electrospinning device be removed from the fibre collector (aluminium foil) without affecting the orientation of the rubber fibres for use in reinforcing...
26 July 2024 8,281 0 View
The aim of the research here is to prevent the propagation of the crack in the fabricated elastic medium with useful applications.
25 July 2024 9,976 3 View
I synthesised a nanocarrier by conjugation MOF (MIL-100) with folic acid for use in chemotherapy but the samples didn't dissolve completely in aqueous solution or DMSO. Instead, they only...
19 July 2024 8,522 0 View
I have conducted virtual screening using Schrödinger on a database of 17,000 molecules. Unfortunately, I cannot use the system with the Schrödinger license at the moment. I am trying to find a way...
18 July 2024 2,881 4 View
Hello, I would like to ask which is the best terminology to use for describing a negative control in an experiment (drug testing in-vitro, viral infection): NC (negative control) or NTC? Thank you...
18 July 2024 4,183 2 View
Dear All, I need to deposit Glutathione on to ready made PCL nanofiber composite, how can I physically immobilize? which way of incorporation do you recommend, physical deposition or...
18 July 2024 9,725 1 View
15 July 2024 2,414 1 View
How to calculate percentage cumulative drug release when, Total volume of dissolution media = 250ml Added formulation was equivalent to 10mg of drug Sample withdrawn = 1ml each time Sink condition...
15 July 2024 4,192 1 View