While running the program in silvaco, the error (Process interrupted by signal SEGV) occurs when the solve statement appears in code, for example:
solve name=anode vanode=0 vstep=0.5 vfinal=2.5.
hi Gaurav,
this type of error in the run time shows ill defined statement for the simulation. there is no problem with the solve statement you have mentioned. i suggest you to please check meshing or material & models you have defined.
hope it helps.
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View
One of my colleagues said, "the impedance you can measure with the three electrodes and with the specific sequence varying the frequency" Is it possible to configure the potenciostat without the...
21 February 2021 418 2 View
Hello everyone Do you have any information about this error 'The experiment was stopped by a potential overload on Vs (auxiliary electrode)' in Origamaster software? I tried everything possible,...
19 February 2021 3,152 7 View
The experiment is really simple. When I do a bulk electrolysis with 1% TFAA (ACN solution) to get dihydrogen, what is going to be oxidized? (working electrode graphit, counter electrode platinum,...
18 February 2021 4,430 1 View
I am working on cathode material. I have made different Li-ion coin cell against Li metal using commercial available cathode materials such as LCO,LMO, LFP and NMC and also with the lab...
18 February 2021 1,450 3 View