I faced a FATAL error while preparing Docked Proteins for MD simulation using Amber20.
But this error does not occur while performing with non-docked protein structures. Is this problem is due to Autodock?
Use docked ligand molecule (you have to convert one docked conformation from PDB to PDB file format) and merge with protein's PDB file not PDBQT file.
USE PDB FILES FOR BOTH RECEPTOR and LIGAND.
Kiran Lokhande
Dear Sir, I have converted the file into PDB from PDBQT. After that, I faced a problem.
While running the following code, I got an error.
saveamberparm REC protein.rec.gas.leap.prm7 protein.rec.gas.leap.rst7
But, this error did not occur while performing with the Non-Docked(Structure retrieved from PDB) Protein structure.
Hi Jagadeesha,
The following tutorial can help you:
http://ringo.ams.stonybrook.edu/index.php/2018_AMBER_tutorial_with_1c87
Instead of checking only the mRNA level, I want to check the active protein level of MMP-1 in Liver tissue from mice. How can I do that?
03 March 2021 1,763 2 View
I want to analyses the proportion of swimming sperm of three species of fish in two salinities. To analyse the proportion of swimming sperm in a Generalized Linear Model, I would use a Binary...
03 March 2021 2,297 3 View
03 March 2021 8,272 1 View
Hi. Please tell me what guidelines should i need to follow for questionaries' type research work in India. It is not hospital based work, we are conduction basic institutional based qualitative...
03 March 2021 2,037 3 View
Hi, I implemented a code to gabor filter cifar10 data but the images after being filtered and stacked are not clear like the original images. I think the problem is in the way I am using the...
03 March 2021 6,317 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
03 March 2021 5,360 2 View
The term miscibility refers to the single-phase state in thermodynamics. I do not mean the compatibility of different components. To determine the miscibility I know several techniques such as...
03 March 2021 4,107 4 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
02 March 2021 5,204 3 View
How to calculate the RMSD values for a MD simulation using MOE?
07 August 2021 0 0 View
When I tried to energy minimization my system, I got fatal error as below. Fatal error: Atomtype opls_116 not found Although I've already added this line: ; include water #include "oplsaa.ff/spc.itp" to [molecultype] directive in my topology.
16 June 2021 0 0 View
I have tried to download the 64-bit version of MGLtools however, as many times as I have downloaded and uninstall the programs, an error arises that the app needs to be updated. Thank you.
03 March 2021 5,997 2 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
Hello, I'm fairly new to ARENA and I have the following problem: I have two queues in which, in each queue, a different order type arrives (both having an arrival rate of exponential 10). Order...
02 March 2021 2,431 3 View
Hello, I have a mechanism where air rises due to convective flows. In this simulation, nothing is driving the air except this. I understand that the Boussinesq approximation only works for small...
02 March 2021 4,910 3 View