Kindly assist about the evaluation of the concentration of the standard preparation against an independent standard preparation, prior to determine the selected sample calibration curve graph.
Please advice on best method approach to choose suitable column for HPLC to analyze targeted samples.
07 August 2018 4,700 0 View
Professional advise will be appreciated, What potential risks if my sample solvent is stronger than my mobile phase in HPLC analysis? What happen or causes and solution
07 August 2018 1,889 0 View
Kindly help with details advantages of Column chromatography over Preparative Layer Plates and disadvantages or vice versa for HPLC analysis
06 July 2018 8,688 3 View
Kindly help the recommended procedure to clean the HPLC column daily before and after used
06 July 2018 1,880 2 View
Which method of separation is more preferable, HPLC, NMR or GC for the determination of diatereoselectivity in polar or non-polar aldol products. What are the advantages or disadvantages of HPLC...
05 June 2018 7,753 9 View
I need comprehensive procedure for the determination of diastereoselectivity by H NMR in the reaction mixture?
05 June 2018 7,161 2 View
Please, I have problems with ChiralPack IB column, can anyone suggest any possible solution because having poor baseline and can't find corresponding peaks.
01 January 1970 8,562 0 View
Results of single-case research designs (i.e., n-of-1 trials) are often evaluated by visually inspecting the time-series graph and computing quantitative indices. A question our research team is...
03 March 2021 687 1 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I want to make a stacked bar graph with showing each data value as dots. I tried with graph pad prism, version 6, but could not succeed. Does anyone have tried before making such graphs?
01 March 2021 9,383 1 View
Its effect appears in real part of ac conductivity also. Can anyone suggest any reason behind it?
26 February 2021 3,487 3 View
I have a permission from X company to use their graph from a report, but they have a reference in the bottom left corner of the graph as follows: "Source: Database Y". Is it OK to use this graph...
24 February 2021 2,269 3 View
i am trying to download x'pert high score software, but can't download it. please do suggest software for phase analysis
24 February 2021 5,687 4 View
24 February 2021 1,365 3 View
Hi all, I am looking for a graph or a relation that relates the degree of saturation and the shear wave velocity for the marlstone. Looking forward to your suggestions Best Regards
24 February 2021 9,690 1 View
Hello, I have run into an issue that has sparkled a debate at work: is the LLOQ/ULOQ impacted by injection volume under the following circumstances: 1) Same dilution factor of all samples 2)...
23 February 2021 9,159 3 View
Hi all, I have a question regarding calculations using the Pfaffl method. I have 3 groups per experiment: 1 control group (calibrator) and 2 treatment groups with 6 to 7 biological repeats per...
19 February 2021 8,351 2 View