If you have .txt file with three columns: freq Z' Z' you can simple open them in ZVIEW. Or you want to convert it for another purpose in these formats?
Yes ofcourse Mr. Marius Zienius. But If we try to fit using ZMAN impedance analysis software we need data's in .*wdf,.*wis,.*seo or .*sde formats. Then oly we can give our input datas for fitting. So if possible anyone can kindly help us to convert the file extensions. @ Mr. Kotagiri Gangaprasad, It's possible to do with ZView....And also ZVIEW software is freely available in internet but ZMAN is not a free software we have buy licence key for activation....
I have used Zview to make equivalent circuit for EIS. However, I not yet understand the meaning of the component of elements in equivalent circuit. For example, Warburg element has 3 parameters (Ws-R?; Ws-T?; Ws-P?) and CPE has 2 parameters (CPE-T?; CPE-P). Please help me, thanks!
It does look like no consensus reached on. So adding my bit. To use text files in zview, one has to save it as txt(MS.dos) file with three columns; frequency, Z' and Z". once a file is opened in Zview using this method, it can be exported into the .z file. Though i am not sure it is openable in ZMAn (i dont have that software). hope this bit helps.