How much is the ITO or CTO workfunction?
These are opaque metal, used in image sensor as metal contacts to reduce the reflection of incident photons.
The work function of ITO is around 4 eV. It depends on the deposition technique.
Please note that a) ITO is not a tin oxide, but indium oxide doped with around 10% tin and b) it is not opaque but transparent.
Is there any reference show the work function of metals?
I am going to simulate different metals in SILVACO TCAD. I must be sure about the exact value of work functions. I need references which could be available to reference in paper.
I would like to create a small guide containing the meanings of the names .. Thanks to everyone who cooperates with me in achieving it.
03 March 2021 5,266 4 View
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
Preference in terms of the scientific aspect
28 February 2021 796 2 View
I build a model of 4 regression equations (probit and OLS) in R studio. I need to take the weights of observations into consideration. While it is simple to do so for every regression equation,...
27 February 2021 1,233 1 View
I am working on TiO2 composite material and the results of XRD have a lot of small/junk peaks and while I apply a smooth filter in Origin then the other characteristics peaks disappear so anyone...
26 February 2021 8,183 3 View
While performing the Linear regression analysis in SPSS version 26.0.0. my intermediate/mediation variable goes to the excluded section. Please share your valuable suggestion "How to restrain the...
25 February 2021 4,591 5 View
i have frequencies of bridge that are effected by mass of vehicle. the problem is when any vehicle pass the bridge it would add the its mass to the bridge mass ultimately mass of the bridge will...
22 February 2021 10,004 3 View
18 February 2021 6,665 6 View
Hello, I have a question. there is a circular thin foil which vibrates in vacuum, the foil restricted and moves up and down. it is like a diaphragm between two pipes . both sides are in vacuum but...
18 February 2021 8,075 3 View
Greetings, I was wondering what is the optimal way to connect the reinforcement at the top of the pile (the part that connects to the raft foundation): -The pile bars are left straight and...
16 February 2021 2,007 3 View
Do you have some recommendations approaches on Image processing and classification of plant diseases using TensorFlow/Keras?
02 March 2021 1,493 4 View
Working on chandrayaan-2 DFSAR data, there are three datasets available: 1) Slant range image data product: The slant range complex image file. Each pixel is represented by two 4-byte floating...
02 March 2021 8,481 3 View
I would like to research on MR images (0.5T and 3T). Can you please suggest some websites that I can download dataset including both 0.5T and 3T MR images? Thank you.
02 March 2021 7,735 3 View
I am a research scholar working on heavy metal stress on plants. I will be doing biochemical characterisation( protein, carbohydrate, proline, antioxidant enzymes and many more assays) at interval...
01 March 2021 6,999 3 View
I try to check the uv-vis absorption of Indium nanoparticle. Now I am measuring in solution, can I measure it in the form of a film?
01 March 2021 930 3 View
Favourable conditions of base pressure, rate of deposition. Also, by which characterisation technique to be used to verify the thickness of the deposited film.
28 February 2021 3,640 3 View
I am trying to obtain the response and recovery times for my gas sensor device. It appears the the response/recovery times are primarily dependant on the flow rate of the gas I inject into the...
26 February 2021 1,511 3 View
The limit test I'm referring to is USP method II. In this procedure you need to dropwise add 6N of NH4OH to the sample until it the pH is alkali. After that you need to dilute and add HOAc until...
23 February 2021 2,049 3 View
How to do acid digestion of soil sample with 3:1 aquaregia in an open vessel?
23 February 2021 3,053 7 View
I notice that upon washing and air-drying of my RGO/SPCE surface and characterizing again via DPV, the current response towards ferricyanide probe significantly decreases. My worry is that the...