I want to know the type of mixtures, their characteristics, uses, mixing mechanism and forces involved
I have also attached TGA and DSC analysis of biosynthesised nanomaterial.
30 May 2024 1,565 1 View
Hello I am seeking detailed protocols for the molecular diagnosis of Friedreich Ataxia. Best wishes Saqib
13 May 2024 1,448 2 View
Reply in sense of current trends among researchers
20 January 2024 7,075 2 View
TEM images showing particle size of 2-5nm while when I have calculated crystallite size from XRD using Scherrer equation 13-15 nm approximately.
04 December 2023 7,185 9 View
I have synthesized sulfide nanoparticles using biosynthesis approach of size 20 nm. Previously reported papers shows both UV and PL peaks. UV graph shows only peak of protein at 280nm while PL...
10 July 2023 5,161 1 View
I have synthesized RuO2 nanoparticles. But Specific capacitance showing major difference between the values that we get from CV curve and GCD curve.
16 April 2023 3,368 2 View
I have bio-synthesized RuO2 nanoparticles at room temperature. TGA and DSC graphs are attached.
20 March 2023 6,708 3 View
I have synthesized RuO2 nanoparticle at room temperature at pH 7, facing an issue regarding binder. Its getting dissolve when suspended in electrolyte(H2SO4). Also please help which electrolyte...
19 January 2023 7,126 10 View
I have synthesised quantum dot using green synthesis. Uv vis spectra show peak at 270 nm(protein peak) and 400nm(quantum dot peak). Excitation wavelength for PL measurement is 390nm but i get...
11 April 2022 9,752 10 View
The following references described a method for determining M/G ratio using CD but what if there are different Molecular weight alginates and what the CD spectra will look like for M/G < 1?...
23 February 2022 8,360 0 View
I tried to make slurry for NCM cathode but there was problem in coating process. The detail of my experiment is following; The ratio between active material(NCM811), conductive additives(Super-P)...
08 July 2024 7,327 4 View
Hi, I am doing analysis of Transystem inc. Downconverter model AiDC+1746D with RF=2216-2300MHz to IF=470-554MHz. The issue that I am unable to find frequency synthesizer and mixer, only 6.8MHz...
09 June 2024 8,378 7 View
i make a design topology of mixer For my graduation project working at 28 Ghz on cadence with UMC pdk and get this result S(2,1) 3.5db but when trying to make same topology with another pdk on...
09 June 2024 9,729 3 View
Hello. I conducted batch leaching tests with samples of construction and demolition waste with adhered paints to assess the influence of the paint on the release of contaminants in the leachate. I...
23 May 2024 4,033 1 View
Hi all, I'm looking to mass mark Solenopsis xyloni ants during an experiment. For this experiment, I'm allowing the whole colony to feed on three feeders, and I want to mass mark all the ants...
13 April 2024 9,988 2 View
Hi 👋 I hope this message finds you well. I am currently collecting data on the design of a reactor system operating at 200 bar pressure and 300 degrees Celsius temperature, with a reactor volume...
28 December 2023 6,795 1 View
Need to calculate the pressure or force generated ibside a 50ml tube filled with water on a Virtex mixer at 2500 rpm
06 December 2023 1,054 2 View
I want to create a image dataset for training YOLOv8 model for an autonomous robot working in steel structure assembly site. As it is difficult to get specific dataset related to steel structure...
29 November 2023 9,157 3 View
Greetings Everyone, I need some suppliers which can provide Protective Microwave Transparent Paint for Antenna PCB. Kindly let me know the details of the suppliers.
29 October 2023 2,580 1 View
Is it possible to remove the titanium-based coating using any solvents/ acids or other chemicals from the steel without affecting the surface of the steel?
29 September 2023 8,427 1 View