When we have several samples, do we need to run all samples on TOF LC/MS or a composite sample is viable to be run? Please guide me. Thank you.
Approximate concentrations are require in compared with the WHO permissible limts
11 August 2024 2,723 1 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
What is the method for analytically calculating the wear and service life of polymer-polymer sliding pairs?
04 August 2024 1,078 1 View
I want a model that is balanced with accuracy or speed, faster rcnn has high accuracy while yolo have fast speed. i am thinking to combine them to get a hybrid model to achieve both speed and accuracy
02 August 2024 3,104 0 View
I used humic acid at 0.044 g/kg soil in my pot experiment. But finally, I have to recommend kg/ha. Each pot's soil weight was 11 kg. What is the solution?
02 August 2024 7,186 6 View
What information we can get from PXRD analysis other than from SCXRD analysis of a crystal ?
30 July 2024 6,261 4 View
Suggest one of them 1. Teflon-lined stainless steel autoclave: 2. Alumina (Al2O3) ceramic container
30 July 2024 7,326 1 View
If the pairs are similar, will it reduce the adhesion due to electric charges?
29 July 2024 3,185 2 View
I've attempted to use this method to synthesize copper nanoparticles. Copper nanoparticles can be synthesised using a variety of precursor materials. CuSO4, distilled water, NaOH, and EDTA are...
28 July 2024 8,027 3 View
Hi everyone, I have extracted DNA from a biogas bioreactor using Qiagen kit and prep cDNA library then used this library as template to optimize primers for qPCR (taken from papers). Some of the...
23 July 2024 1,329 5 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
I am analyzing cherts from different sources found within one specific geologic formation using ICP-MS/ES. My committee was asking this question about my analysis. I was not sure how to answer this
05 August 2024 7,902 3 View
Have you ever seen a LC-MS/MS method uses both internal standards and external standards (in matrix matching purpose) but the concentrations of internal standards are outside the calibration curve...
05 August 2024 3,084 6 View
Hello guys! Do you have experience running a Oaxaca-Blinder decomposition on R applying person weights. How do you suggest doing it? I have a variable PERWT which gives more information on how...
04 August 2024 6,033 0 View
Hello Everyone I have a question about structure for connectivity analysis on sources. My goal: preprocess and cut data into trials create headmodels, using template MRI file perform source...
30 July 2024 2,744 1 View
When I run autogrid4 it says: autogrid4: ERROR: Unknown receptor type: "Cr" -- Add parameters for it to the parameter library first! Look forward to your reply.Thank you so much!
29 July 2024 488 0 View
I am trying to run a restart analysis, which imports deformed configurations of parts from a generated ODB file. It runs fine in Windows OS but when I try to run it in Linux OS, it is giving some...
29 July 2024 9,572 3 View
Our department has recently acquired an HPC (High-Performance Computing) system, and I'm thrilled to take my molecular dynamics calculations to the next level using Desmond. I used to run my...
28 July 2024 6,553 1 View
I am using the Polyomics Integrated Metabolomics Pipeline (PiMP) for metabolite feature analysis. After annotating my data, I have encountered cases where multiple potential metabolites are...
24 July 2024 5,789 0 View
I am preparing to run a lot of samples on a 384 well plate and I wanted to test if any well in my PCR machine is dead so as not to lose any data. I would really appreciate help with how I can do...
24 July 2024 8,172 1 View