I am using a DELTA G3T receiver and use it for real time data logging using GREIS commands directly to PC. For the purpose, I use NetView software.

I can record GPS only/ GLO only/ GAL only or any combination of the constellations without problem using GREIS command sets.

Now, I want to log data for any of the constellation for single and dual frequency modes - as the rcvr supports triple freq for GPS and dual freq for GLONASS and GALILEO.

1. Can anybody please tell me how to operate the receiver in single frequency and dual frequency modes using GREIS command sets

2. Can anybody please provide me the the real implications of the "satellite status" (0/ 1/ 2/ 3 etc.) shown in the measurement screen (attached below). As suggested in manuals:

0 - CA/L1 data used for position computation

1- P/L1 data used for position computation

2- P/L2 data used......

3- ionosphere-free combination used .....

So, if the status is shown to be '0' - does it mean it operating in single freq (L1 only) for position solution ?

and if the status is '2' then the rcvr is using L1+L2 (dual freq opeartion) ?

and if the status is '3' then the rcvr is using all available freqs for ionospheric correction ? >>>> AM I RIGHT OR OTHERWISE ?

The manuals are not sufficient for clear understanding of the issue.