Hi,

I have deposited 100nm Au on 5nm Au using e-beam evaporation and conventional photo-lithography techniques. I used ~5nm Ni as an adhesion layer for 100nm Au, so basically the structure is Au 5nm/Ni 5nm/Au 100nm.

The lift-off of the 100nm Au is extremely hard. I usually rest the sample in acetone for couple of hours so the lift-off is complete. However, in this case even after days, the lift-off is not complete and there are lots of unwanted pieces of Au on the surface. I try to use ultrasound (40kHz) as little as possible because it damages to the structures and removes the main metal layer as well. However, for these samples I apply ~10sec ultrasound, but after ultrasound the quality of the 100nm Au is bad and so much of metal is gone.

Worth mentioning that I dip the samples in HCL (37%) for ~3sec and H2O for 5sec before the 100nm Au deposition to remove any unwanted organic particles on the surface.

Is there any solution to improve the deposition/lift-off process, so the final 100nm Au has a good quality and shape?

Thanks for your time!

Amir