D and G band in CARBON DOTS observed at 1304 and 1441 cm-1 unlike 1348 and 1581cm-1. Can someone help me in knowing the reason behind this shift. I am attaching recorded raman spectra of carbon dots for reference.
I have used 300 oC as degassing temperature for BET analysis of clay nanoparticles, it got charred after degassing. Why does this occur?
06 June 2019 842 5 View
XRD peak of bare carbon dots coming at 19 degrees and surface functionalised carbon dots with hexadecylamine coming at 19 degrees and 20-22 degrees, can someone help me in analysing these peaks...
25 March 2019 1,128 5 View
I see circular rings in HRTEM image of carbon nano particles, Can someone tell me what does it represent?
18 March 2019 8,111 3 View
I am trying to perform protein aggregation studies using GROMACS. How can I put 20 or more replicas of the protein which are equally distributed in the simulation box?
04 March 2015 2,072 1 View
08 August 2014 8,240 4 View
I have recently started working on NGS data and gonna start working on variant calling methods. VarDict seemed to be at the top of all methods, but I was wondering what could be the possible...
01 January 1970 1,039 4 View
Dear All, I want to quantify carbon deposition on the surface of the CuZnAl catalyst. I have tried thermogravimetric analysis, but I've got weight gain as the active Cu- get oxidised. Does anyone...
01 March 2021 1,907 3 View
I am a student of MS Environmental Engineering and started my research phase. I am working on metal removal ( chromium iii ) by using activated carbon prepared from the agricultural feedstock. So...
01 March 2021 5,475 2 View
Dear all, I am trying to perform a MD simulation about the interaction between CO2 and a polymer. I create my model, solvate it and perform the NVT and NPT equilibration. Now I am not able to...
26 February 2021 10,014 3 View
Has anyone ever tried to deliver CO2 with a CGA 300 regulator? I know that a CGA 320 regulator is standard for CO2. The issue is that I currently do not have any free CGA 320 regulators. I also...
25 February 2021 3,292 3 View
How do I run a a priori sample size determination for non-parametric tests, like the Mann-Whitney U-test and the Kruskall-Wallis or other non-parametric tests that accord with the unpaired t-test...
24 February 2021 166 6 View
Respected Professor's i hope you are doing well and happy. i need some information about carbon Nanotubes. before blending the CNT with the matrix the CNT has been introducing in some treatments....
24 February 2021 5,383 5 View
I need to clean the hydrocarbon contamination on the carbon substrate of TEM grid. However, I heard that substrate could be broken by the powerful plasma. My substrate is pure carbon, with ~3nm,...
23 February 2021 3,262 5 View
Hi, me and my team mates are currently planning to pursue the topic of Activated Carbon from Coconut as a Water Filter. And we would like to ask for your suggestions and knowledge on what specific...
22 February 2021 6,569 3 View
21 February 2021 7,561 4 View
I would like to ask what other properties of water (pH and such) shall be analyzed and evaluated to test the effectiveness of activated carbon from filtering the contaminants present in the water?
20 February 2021 9,422 8 View