Please help me I want geant4 codes for simulation of neutron detectors?
You could be interested in this paper "Characterization of the Neutron Environment and SEE Investigations at the CERN-EU High Energy Reference Field and at the Pic du Midi"
How much G4 experience do you have? Fundamentally you just want a block of semi-conductor with the relevant physics in your physics list.
http://geant4.web.cern.ch/geant4/support/download.shtml
Dear All, The neutron cross section of element generally falls with the increase in neutron energy. But in U-238 the fission cross section at Neutron energy of 1MeV is 0.3 barns whereas it...
02 March 2017 1,774 4 View
Is there any mathematical formula there for the ideality factor of the diodes? I will be very much thankful for the above. Please send the mathematical expression for it.
08 September 2016 7,007 5 View
In the radiation detector the pulse shaping circuit consists of CR-RC circuit and amplifier.The function of pulse shaping amplifier is to improve Signal to Noise ratio.It also act as a filter to...
08 September 2016 8,565 4 View
Generally there are three types of noise is present in the semiconductor radiation detector.These are Thermal Noise,Shot noise and Flicker Noise.The thermal noise is removed by operating the...
08 September 2016 9,355 2 View
Dear All, Is there any technique other than the CVD to coat the Enriched Boron-10 on the Si surface? I will be very much thankful for the reply. Thanks & Regards Manoj
08 September 2016 8,686 0 View
In the commercial available charge sensitive preamplifier for semiconductor radiation detector.Generally the HV(High Voltage) bias given to the semiconductor detector is through the charge...
08 September 2016 4,154 4 View
I have performed the neutron irradiation on the PIN Diode. I have found that the forward bias cut-in volatge has been shifted. Why these shift been observed in the neutron irradiated PIN...
06 July 2016 8,002 3 View
In the depletion region only uncovered ions are exiting then why we have the maximum electric field at the center of the junction?
06 July 2016 7,472 6 View
The function of the Guard ring is to reduce the leakage current and make the PIN diode to work at higher potential ? How does the guard ring perform this function? Please some one explain...
06 July 2016 6,690 2 View
Dear All, For the common mode signal the input voltage is calculated as (V1+V2)/2. Why we are calculating the common mode input signal as (V1+V2)/2 whereas in differential mode the input signal is...
04 May 2016 2,090 1 View
Hello everyone, I recently submitted an article to Geotechnical Engineering (Proceedings of the ICE), and the current status has been listed as "EiC Pre-assessment: Ready" for the past 20 days. I...
10 August 2024 6,493 1 View
I need to model an anisotropic material in which the Poisson's ratio ν_12 ≠ ν_21 and so on. Therefore, the elastic compliance matrix wouldn't be a symmetric one. In ANSYS APDL, for TB,ANEL...
09 August 2024 5,048 2 View
Request Python code from this article : Gender equity of authorship in pulmonary medicine over the past decade. THANKS!
08 August 2024 6,242 2 View
Visual Studio Code (VS Code) has become a popular choice among developers for several reasons: 1. **Free and Open Source**: VS Code is free to use and open source, making it accessible to...
07 August 2024 7,013 4 View
I need the python code to forecast what crop production will be in the next decade considering climate and crop production variables as seen in the attached.csv file.
05 August 2024 2,977 3 View
Is it possible to conduct a molecular dynamics simulation to see the effects of a specific carbohydrate on the structure of lipids (e.g., micelle structure)? I am a beginner in this field and plan...
03 August 2024 3,371 3 View
I am using a windows system, what software I should use for hydration shell analysis with molecular dynamics?
02 August 2024 3,143 4 View
The module of the CAD detector is corona Veo. It has been idle for a long time. And it was not well maintained before idle. I have replaced the gas filters and flushed the system with a 50/50...
01 August 2024 7,805 0 View
I am attempting to conjugate PEG to an amino acid at the C-terminus, for the purposes of producing nanoparticles. I have been told that PEG modified with amine groups can be used for this purpose,...
31 July 2024 2,033 1 View
Can we patent a process flow diagram developed using a process simulator but no actual cases is carried out? For example consider a process for certain product manufacture where a new process flow...
31 July 2024 781 1 View