I am looking to improve the sensitivity of the ZnO based humidity sensor?
In this case, is the correct sensitive layer based on pure ZnO or doped ZnO or co-doped ZnO?. For that please help me to solve this problem and thanks in advance.
Interesting question.
Dear all, variuos strategies are possible. Please check the following documents. My Regards
https://doi.org/10.1016/j.spmi.2010.03.006
https://doi.org/10.1016/j.spmi.2012.03.009
https://www.researchgate.net/publication/279247743_Humidity_Sensor_-_A_Review_of_Nanostructured_Zinc_Oxide_ZnO-Based_Humidity_Sensor
https://www.researchgate.net/publication/276096944_Humidity_sensor_characteristics_based_on_ZnO_nanostructure_grown_by_sol-gel_method
https://ieeexplore.ieee.org/document/7233121
https://doi.org/10.1039/C8NA00243F
https://www.scientific.net/AMR.1109.395
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5677101/
https://www.mdpi.com/1424-8220/19/3/519/htm
Thank you for the message
Thank you for this information
Instead of checking only the mRNA level, I want to check the active protein level of MMP-1 in Liver tissue from mice. How can I do that?
03 March 2021 1,763 2 View
I want to analyses the proportion of swimming sperm of three species of fish in two salinities. To analyse the proportion of swimming sperm in a Generalized Linear Model, I would use a Binary...
03 March 2021 2,297 3 View
03 March 2021 8,272 1 View
Hi. Please tell me what guidelines should i need to follow for questionaries' type research work in India. It is not hospital based work, we are conduction basic institutional based qualitative...
03 March 2021 2,037 3 View
Hi, I implemented a code to gabor filter cifar10 data but the images after being filtered and stacked are not clear like the original images. I think the problem is in the way I am using the...
03 March 2021 6,317 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
03 March 2021 5,360 2 View
The term miscibility refers to the single-phase state in thermodynamics. I do not mean the compatibility of different components. To determine the miscibility I know several techniques such as...
03 March 2021 4,107 4 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
02 March 2021 5,204 3 View
I am trying to obtain the response and recovery times for my gas sensor device. It appears the the response/recovery times are primarily dependant on the flow rate of the gas I inject into the...
26 February 2021 1,511 3 View
Due to the unavailability of climate rooms, I want to carry out an experiment that require the use of certain saturated salt solutions especially those that can condition the wood specimen to 35%,...
25 February 2021 8,139 1 View
I am trying to calculate the theoretical density of my ceramics materials. I use the formula below to calculate the theoretical density: Theoretical density = (Molecular weight x No. of molecules...
24 February 2021 3,823 2 View
Dear Research Gaters, Let me first add context to the question. I am looking to simulate the waste management system and resources of a city. The hardware devices I need to simulate include,...
21 February 2021 2,333 4 View
My team is designing a dual channel microfluidic chip that runs air and water. I think we've decided on the NE1000 syringe pump for it's versatility and feedback control. We will be ordering the...
18 February 2021 9,928 2 View
what is the reason film thickness increased when increased doping concentrations give some reasons The measured film thickness is 156, 282, 394, 548 and 681 nm for 0, 1.5, 2.5, 3.5, and 4.5 wt....
17 February 2021 8,987 5 View
Hello researchers! While studying the literature on refractive index sensors, most of the articles simulate their devices with a refractive index ranging from 1 to 1.1, with small steps in...
17 February 2021 1,578 4 View
Our team is designing a smart water C&C dashboard for a smart city initiative. As we look into the current smart water system landscape, we couldn't reconcile to a definitive solution that...
16 February 2021 1,094 3 View
when I put my ZnS solution in the chemical bath, the ZnS oxidizes so there are ZnO peaks appearing because of the reaction with the oxygen in the air, despite the fact that I close the beaker...
14 February 2021 5,778 9 View
I am doing a three point bend test with concrete specimen of dimension 280mm*90mm*90mm. I am putting 2 sensors near the notch with 3cms away from both the sides. the experiment ran for 20 mins but...
13 February 2021 2,990 1 View