I wanted to ask please if some body here has used a CRM of a beach sandy soil sample?I am interested in vanadium contamination within a sandy beach in Dubai.
I have tried to look in few CRM databases but could not find, Any help will appreciated.
Not sure what a CRM is....but trace level metal analysis is typically done using ICP-MS (Inductively Coupled Plasma - Mass Spectrometry). You will need an extraction procedure for sample prep. You can look up ISO and USEPA methods online. For USEPA, it might be the 6010 series of methods. If you are in Dubai, you can call up the Al Futtaim Exova commercial labs. They run an ISO series ICP-MS method after an aqua regia extraction. The MS provides added confirmation of the element - you might be able to get by with just ICP-OES. Good luck!
Regarding the 033 yes we used it plus we used Till 1,2,3,4 for HM studies. Also I would like to mention as long as you are going to use heavy metals protocol digestion such as EPA 3051 microwave digestion, then it will be OK.
Sandy samples will contain high amount of silica and you will not face any interference by using any sand CRM material with 3051because you are going to use HCl and HNO3, no HF
also this thesis may help on Vandium bioavilabilty