What analysis method can be used to detect thiophene in the coke? What method can be utilized to remove thiophene from the coke in order to reduce the sulphur levels?
You can try FTIR to measure thiophene.
You can remove Thiophene by passing H2 through coke.
Dr. Coetzer,
If you use solid based method, please use FTIR.
If you use both liquid based method, please use GC-MS.
Configurations: Rstudio v1.3.1093 Packages: car, lme4, MuMIn, DescTools Model: myGLM
22 January 2021 5,284 6 View
I want to determine the success rate of an personnel selection instrument (interview, assessment center...) depending on the validity of the instrument itself, the selection rate and the base...
29 November 2020 7,190 4 View
Dear colleagues, we carry out a research project in a company neighbourhood/industrial park to promote physical activity in the occupational setting. Using a standardised instrument, I would...
01 March 2020 6,577 3 View
Hello all, For some research on super(sub)critcal fluid extractions, I am examining SFE CO2 systems. On websites of manufacturers of these plants they state that the CO2 used in extraction can...
10 August 2017 5,058 4 View
I want to evaluate the amount of internal cAMP levels. Unfortunately, I suspended my cells of desire in RIPA buffer. Is it possibly, despite the harsh buffer, to determine cAMP levels in an...
23 April 2017 2,996 8 View
30 March 2015 9,071 9 View
I want to use it to analyse dibutyltin in surface water. For tributyltin I have already an internal standard (tributyltin D27) and it is performing very well. I am trying to buy dibutyltin D18...
17 September 2013 5,713 3 View
Electrical conductivity and resistivity of coke during smelting of ores is a pivotal parameter. Measurement of the coke resistivity seems to be problematic and no standard method is available.
13 May 2013 6,958 1 View
Sublimation process
15 December 2012 9,735 1 View
Processes included such as leaching, synthesis, drying
15 December 2012 9,466 1 View
How to calculate the RMSD values for a MD simulation using MOE?
07 August 2021 0 0 View
When I tried to energy minimization my system, I got fatal error as below. Fatal error: Atomtype opls_116 not found Although I've already added this line: ; include water #include "oplsaa.ff/spc.itp" to [molecultype] directive in my topology.
16 June 2021 0 0 View
effect of double bond on the flexibility of polymers
07 April 2021 0 0 View
I am writing to request some information for making polymer color flakes. I would appreciate the help.
17 March 2021 0 0 View
I am at the beginner level in drug design and drug discovery, and I am interested to learn more about this field. Which books are highly recommended to start from and gives me all essential...
02 March 2021 8,437 2 View
The Lanthanide contraction which is the decrease in ionic radii of the elements in the lanthanide series from atomic number 57, lanthanum, to 71, lutetium, is due to poor shielding of the 4f...
01 March 2021 2,272 4 View