I am looking for a software package for building and analysis of pole figures in thin films. I'm having a hard time finding the PoPLA software. What alternatives would you suggest?
Beartex (http://eps.berkeley.edu/~wenk/TexturePage/beartex.htm).
Labotex (http://www.labosoft.com.pl/).
MTEX (https://code.google.com/p/mtex/)
First two programs are not free, MTEX requires MATLAB.
MAUD (http://www.ing.unitn.it/~maud/) is able to process diffraction data and get you to orientation distributions.
GSAS-II, it also can read GSAS .exp file and if u had a ODF u can just us the texture tab to display it.
Hi. Im writing a review regarding the use of high-power lasers and I'm wondering what are the most important parameters in these lasers that i should extract from my included studies? I cant find...
10 December 2021 1,184 3 View
Hi, I'm writing a review about photobiomodulation and I'm wondering how I can calculate the fluence of a laser from its irradiance. like there is this article that has used an Nd: YAG laser at...
04 May 2021 7,428 0 View
I am trying to simulate permeation of gases in polymers. For this reson normally i use the clasic models like dual sorption model but newly i foun dthe non equilibrium lattice fluid model. It...
03 February 2021 1,447 3 View
hi im modelling a ball & beam system in simulink. i modelled a DC motor for it in a subsystem as well and the DC motor has a PID controller. naturally the speed of the DC motor's loop should...
23 August 2020 5,552 1 View
I am searching for someone who can do 3D reconstruction using Micro-CT data. I have the scans but I cannot reconstruct them 3-dimentionally! In my study, we aim to compare voids volume in 4...
06 August 2020 8,067 5 View
I have the refractive indices (n & k) of a thin film. I can estimate the real part of sub-wavelength structures by considering the shape and void fraction using a simple linear relation....
06 June 2020 1,650 4 View
I am using a commercial PS nanosphere (60-70 nm) dispersion in water. The dispersion is diluted in ethanol before injection into Langmuir-Blodgett trough (the stock concentration is 101 mg/ml)....
30 January 2020 5,565 2 View
Hello.I am working on vortex tube. . The information is attached . I have three problems: 1- Temperature contour and is wrong 2- The mass flow rate of cold outlet and hot outlet is false 3-...
14 November 2019 6,346 1 View
Hello We are currently working on the separation of magnesium sulfate salts using NF90 Nanofiltration membranes. We know that our main problem will be to remove the fouling from this salt for...
04 November 2019 2,489 3 View
Hello All, In order to make some calcium test devices, we will be needing to expose calcium pads (100 nm of thickness) to nitrogen atmosphere. We do not expect the exposure time to be more than a...
09 September 2019 7,348 4 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
I would like to learn more about SPSS and Its application especially in regards to data analysis. Please suggest me how I can learn more about it. Thank you so much.
11 August 2024 9,101 4 View
I have reverse sequences (AB1 format), can I base on reverse DNA sequences to perform nucleotide alignment, convert nucleotides to amino acids and deposit the sequence in GenBank database?
11 August 2024 5,138 1 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Willett, Shenoy et al. (2021) have developed a brain computer interface (BCI) that used neural signal collected from the hand area of the motor cortex (area M1) of a paralyzed patient. The...
10 August 2024 7,180 0 View
I'm currently exploring the application of Python in textile engineering, specifically in areas like data analysis, process automation, and the development of smart textiles. I'm interested in...
10 August 2024 7,429 2 View
How can I use the cif data obtained from rietveld refinement extracted via gsas2, for microstructural analysis using ETEX software?
09 August 2024 7,718 0 View
Require for Rietveld refinement in XRD.
08 August 2024 3,081 2 View
Let's say we have a standard, regular hexagonal honeycomb with a 3-arm primitive unit cell (something like the figure attached; the figure is only representative and not drawn to scale). The...
07 August 2024 1,937 1 View
A fungal strain was treated with nanoparticles. We want to do an environmental SEM analysis. So could anyone share your views on preparing the sample? Thank you.
07 August 2024 5,307 1 View