Hello all-
Is there a way to image 4 colors on Leica SP8? We have UV (405 nm), and 45, 476, 488, 496, 514, 561, 633 nm.
I want to use..
AF 488
AF 594
AF 647
I really want to avoid lower than 488 as my cells give autoflouresence. Any thoughts?
Hello, Does anyone know tom20 antibodies that work well for mice? I tried Tom20 Antibody (F-10 and 29) and both did not work very well. Thanks!
31 December 2019 1,162 1 View
Hello, What would be the best marker for FLT3L-induced bone marrow dendritic cell for flow cytometry?
08 September 2018 6,653 0 View
All- Is there a way to count lymphocytes from purified spleen using flow cytometry that will give comparable cell # from hemocytometer?
11 December 2017 9,789 4 View
All- I was wondering if you can use cell viability test using live/dead for flow cytometry in lieu of MTT assay? Is this acceptable?
10 November 2017 8,863 3 View
All - I saw different methods of measuring NOX2 activity using luciferin-based or NADPH reduction and etc.. What is really the best way of accessing this activity? Thanks!
10 November 2017 8,306 1 View
Hello all, I treated with a type of adjuvant I am interested in with DC 2.4 cell lines (DC-like murine cells) for 3, 6, 12, and 24 hrs interval. I then lysed the whole cell extract and did WB...
03 April 2017 9,122 2 View
11 December 2016 8,546 0 View
Dear all, I have a lot of non-specific bindings for one of the staining for intercellular staining in cells derived from mice. My 1' antibody is from rabbit. If I am doing just one color for ICCS,...
10 November 2016 6,752 4 View
09 October 2016 3,793 1 View
Dear everyone- Has anyone tried to make NEB turbo competent cells in the lab? Is there any good protocol for this? Thank you so much for your time.
08 September 2016 9,716 0 View
Hi all, I am validating a polyclonal antibody raised against human ANT4, through WB and ICC. In most of my controls, the antibody shows very little off-target binding, but when I pre-incubate the...
03 March 2021 5,999 3 View
I have selected brain tumor images ...but now found that already lots of research done n this topic.
03 March 2021 5,774 3 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
Need to image mesoporous silica nanoparticles using the TEM. Also, need high resolution TEM images to see the mesoporous structure. Kindly suggest what kind of grids to use. Thanks, Shatadru
02 March 2021 1,787 2 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
Dear Colleagues, After running Western blot on PVDF membrane and detection using ECL, I would like to stain my PVDF with colloidal gold to be able to allign the ECL image with total proteins on...
02 March 2021 7,829 3 View
I need to prepare a solution of Napabucasin (inhibitor of cancer cell stemness) in dichloromethane. The drug is expensive, so maybe somebody already tried to do it. If it is soluble, what is the...
02 March 2021 9,945 3 View
im working now on TPV solar cells and metamaterials and i realy need our help in CST microwave i have a tpv cell simulation and i want to extract particullarly the absorbtion of only the active...
02 March 2021 2,246 2 View
I would like to research on MR images (0.5T and 3T). Can you please suggest some websites that I can download dataset including both 0.5T and 3T MR images? Thank you.
02 March 2021 7,735 3 View
Hello, I have classified 10 S3 OLCI images from the same area (althouth not the same size and/or quadrant) and I would like to do a final image using the mode of the pixel of these 10 images. I...
01 March 2021 9,874 3 View