14 Questions 30 Answers 0 Followers
Questions related from Muhammad Shoaib Ahmed Khan
For a techno-economic analysis of pyrolysis of olive mill waste water sludge, I am looking for the price of fluidized bed reactor. The feed rate is 4000 kg/hr.
10 March 2021 6,604 2 View
Hello I am simulating a biomass grinder in Aspen Plus. The feed rate is 100 tonnes per day. Initial size is 200 mm and final size is 40 mm. I am using a jaw crusher type. When I perform integrated...
09 February 2021 8,105 11 View
I have to design a fluidized bed reactor for pyrolysis of biomass. The feedstock flow rate is 4000 kg/hr. I was able to determine the minimum fluidization velocity. How can I specify the diameter...
11 December 2020 5,796 9 View
I would like to know if Aspen Plus can be linked with MATLAB or Python?
24 September 2020 2,148 2 View
Has anyone successfully modelled an absorption cooling system using Aspen Plus?
24 September 2020 5,471 1 View
Hello Does anyone know how to define a Fortran user kinetics subroutine in Aspen Plus?
18 February 2020 3,975 2 View
I am modelling pyrolysis of biomass and I want to know if it is possible to classify bio oil as non conventional component?
29 January 2020 4,322 5 View
I am using Aspen Plus to model the pyrolysis of olive mill waste water sludge for production of bio oil. I have the ultimate analysis and proximate analysis of biomass. I also know the percentage...
20 September 2019 1,527 12 View
I am working on solar absorption cooling system in TRNSYS as part of my MSc thesis. I need to justify my results and validate the model. How can I convince the evaluation committee that my model...
24 May 2016 4,519 7 View
I am simulating a project and I have to run a lot of simulations like calculation of solar fraction at different collector tilt angles.Can anybody tell me how to make a table and get the results...
01 May 2016 2,036 10 View
The rated capacity of absorption chiller is 424.93 tons in type 107 hot water fired absorption chiller. My cooling load is 112 tons. Fraction of design load is 0.26. Capacity is given by following...
01 January 2016 3,957 2 View
I want to simulate a system which turns off on holidays like Saturday and Sunday. How can I define it in the simulation in TRNSYS?
10 June 2015 7,176 7 View
I am simulating a building which has about 48 tons cooling load. When I try to connect cooling coil type 697 with absorption chiller type 677, I get the following error message. "TRNSYS Message...
14 April 2015 7,613 2 View
1)We made building on Google sketchup 2)We then imported it on Trnsbuild where we defined all properties eg ventilation,infiltration,building material . 3)Now we want that trnsys calculate...
10 March 2015 1,030 4 View