If the design pressure is equal, the gas blowby will not cause overpressure in the downstream equipment. Conversely, If the design pressure of the downstream equipment is lower than the upstream equipment, when control valve fail, the gas will flow to the downstream equipment and cause overpressure. Gas Blowby case is applicable if only the design pressure of downstream equipment lower than the upstream pressure.
Bachir Achour Thanks a lot for response. Yes, you are right regarding downstream equipment design pressure, while my question is about difference between gas and liquid overpressuring.