Recently I'm working in electrocoagulation of dye effluent with titanium electrode, what are the other electrode can be used instead of titanium ? Why?
for drought management
04 April 2017 9,012 3 View
hi all, i need to prepare return on investment document for an plastic component including tooling cost. but i have only little knowledge on this. Is anybody having sample ROI document? This is...
20 November 2016 1,408 3 View
how to calculate electrochemical active surface area of electrode in CV curve
04 February 2016 7,222 4 View
which parameter affect the gain of the antenna.? how air substrate improves the gain..?
21 March 2015 5,580 16 View
i am designing array antenna. if the array elements are placed (patch) top and bottom for reduce the space. how to make the same phase to excite the top and bottom elements of the antenna.?
08 December 2014 4,737 4 View
.
26 October 2014 7,562 8 View
Hello all , I am reading a research paper that talks about the (P,Q) outer generalised inverse. In order to find some examples in arbitrary Banach spaces, I am excepting the answer for the above...
02 October 2014 7,531 5 View
i need to calculate the market price of mechanical components. I know the tooling cost of this component. Is there any other parameter are needed for calculation?
01 January 1970 3,188 3 View
In hard template method, why sodium hydroxide is used to remove colloidal silica for synthesis of ordered mesoporous carbon
01 January 1970 9,221 3 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,628 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,623 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,537 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View
I am trying to drop cast 2D Materials on Glassy Carbon Electrode for Cyclic voltametry and EIS purpose. What would be best binders to use?
23 July 2024 5,776 2 View
I have attached the charging curve from the battery tester for review. I need help on what is happening
21 July 2024 6,897 2 View
I want to know that n-doped side of solar cell is connected with positive or negative electrode.
20 July 2024 1,347 2 View