Why does the UV absorption spectrum of red quantum dot film not exhibit a significant absorption peak? As shown in the following Figure.
Hello Wenxin Lin.
Maybe your quantum dot does not abosrb in this region. There are materials that absorb in 200 nm, or in wavelength > 700 nm. Have you tried these possibilities?
Best regards,
Ricardo Tadeu.
Ricado's suggestion is correct. If the colour is red, the material absorbs at the blue end of the spectrum and you can see that beginning in your data
U may follow this
Article Fluorescent N-Doped Carbon Quantum Dots: A Selective Detecti...
I have carried out MFC experiments on three different volumes, 50, 500 and 1000 mL of wastewater. Results after MFC treatment shows that TDS and EC are more in larger volumes of water i.e. TDS and...
09 August 2024 9,621 0 View
Pig slurry is rich in major and minor nutrients. Is there any way to improve / Enrich its manure quality to be used in agriculture organically ? please share your knowledge.
09 August 2024 5,605 2 View
Hi, I'm currently working on a project where I need to plot the atom-projected band structure using GPAW. I've been able to calculate the band structure for my material, but I'm having trouble...
07 August 2024 268 3 View
Hi, we have measured tryptic peptides using both DDA and DIA method on QExactive. In DDA replicates i saw unusual intensity drops occurring at the same sections of chromatograms in DDA replicates...
07 August 2024 3,218 4 View
Hi How can this equation Ln(LA) = 1.038 + 0.89 ln(X) be applied to calculate the leaf area of a tomato? Can you explain with an example and what is the substitution of Ln and ln?
06 August 2024 2,508 2 View
I aim to be as skeptical as possible regarding whether a pair of orthologous genes results in the same phenotype in their different but related bacterial organisms under similar environmental...
05 August 2024 6,787 4 View
I ran a SDS-page of a bacterial lysate and I want to quantify protein concentration in a specific band. I was thinking of using a standards ladder or make some standards are different...
05 August 2024 9,805 3 View
XRD Analysis is showing only Calcium carbonate. It is not showing other compounds. Can anyone help me get the other compounds
04 August 2024 3,019 3 View
I work on MCF7 cell cell for anticaner purpose and I wa to do drug preperation the drug ( secondary metabolites extracted from Aspergillus) My question which solvent is better with these secodary...
03 August 2024 4,725 2 View
Machine learning (ML) has shown great potential in predicting the compressive strength of concrete, an important property for structural engineering. However, its practical application comes with...
03 August 2024 2,546 2 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,800 2 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
A website software of Blackbody radiation law expert software can used through the following web site. http://39.105.188.151:3000/index
07 August 2024 1,706 0 View
For example, I perform passivation process before electropolymerization of Py for adhesion to titanium surface. Is a similar or different procedure required for ITO? If necessary, I would be glad...
06 August 2024 3,176 0 View
What is the prepared reference material that can be used in the ICPE-9820 Shimadzu Japan instrument, which employs inductively coupled plasma optical emission spectrometry (ICP-OES) to measure...
06 August 2024 1,896 1 View
Hello, Can anyone provide me with the absorption coefficient of methane gas at 7.7 um? Any reference?
06 August 2024 980 5 View
Hi, i would like to simulate an absorption process in Aspen Plus. I want to use the NRTL model und would like to add some individual Henry coefficients. Is that possible and how?
05 August 2024 2,332 2 View
I am interested to know the behavior of dyes toward light. Specifically, Blue dyes re-emit the spectrum, especially from the green zone (known as principal in LED lamps, and blue dyes are known...
05 August 2024 3,290 1 View
Hello, everyone. I have tried to determine carrier motilities of some materials, by Density Functional Theory, using Quantum ESPRESSO. There are a few methods to do it, like a package called...
04 August 2024 8,893 1 View
Why is TLC not a form of partition chromatography and paper chromatography not a form of absorption chromatography?