GCD in red color is against charging & discharging current of 8E-7 A with cut off voltage 0.5V which is ok, but for charging & discharging current of 6E-7 A (green color) i am not getting triangular shape GCD curve but it gets saturated atfer chaging and if i decrease the cut off voltage to 0.4V for same current (blue color), in gcd curve after charging to 0.4 V it goes beyond the 0.5 V and gets saturated in place getting discharge, please explane why it is happening so?