Which LCMS-method is useful for find out the mass of tenofovir analogs using LCMS ?
Dear suman,
Abstract
A liquid chromatography-tandem mass spectrometry method for tenofovir
from plasma has been developed. Using Thermo ScientificTM SOLATM CX
plates, sample preparation is fast and efficient, giving excellent
recovery levels for the compound. Separation was carried out on a
Thermo ScientificTM Hypersil GOLDTM UHPLC column with a cycle time
of 3 minutes. Good chromatographic peak shape and linearity over the
dynamic range 1 to 1000 ng/mL was achieved with excellent recovery and
reproducibility.
MS Conditions
Instrumentation: Thermo ScientificTM TSQ VantageTM MS
Ionization conditions: HESI
Polarity: Positive
Spray Voltage (V): 3000
Vaporizer temp (°C): 350
Sheath gas pressure (Arb): 60
Aux gas pressure (Arb): 40
Capillary temp (°C): 300
Collision pressure (mTorr): 1.5
Scan time (s): 0.02
Q1 (FWHM) (Da): 0.7
Q3 (FWHM) (Da): 0.7
Compound: Tenofovir
Parent (m/z): 288.1
Products (m/z): 176.2
Collision energy: 24
S-lens: 115
Data Processing
Software: Thermo ScientificTM LCQUANTM
Dear suman ,
LCMS- mass method of tenofovir analogs using LCMS conditions PDF doc
Please find the attachment
can any one please send me this literature of Amino acid and peptide esters of abacavir: synthesis and biological activity?
06 July 2016 4,955 1 View
Can any body please suggest me which base is suitable between amine and amides reactions while using IPA as solvent ?
06 July 2016 9,059 1 View
can any one please give to me HPLC method for Bisphenol A ?
01 January 1970 1,876 1 View
Can anyone explain this method? Especially the last statement where it says only at 1.5 to 2.5mins was the MS/MS connected to the UPLC. How is that possible, is it a feature in this specific...
11 August 2024 8,141 3 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Hello experts, Does anyone know any free software about retention index prediction ?
08 August 2024 7,403 2 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
I am analyzing cherts from different sources found within one specific geologic formation using ICP-MS/ES. My committee was asking this question about my analysis. I was not sure how to answer this
05 August 2024 7,902 3 View
Have you ever seen a LC-MS/MS method uses both internal standards and external standards (in matrix matching purpose) but the concentrations of internal standards are outside the calibration curve...
05 August 2024 3,084 6 View
I want to perform a CRISPRa/i library screening for candidate regulatory factors that affect pathogenic Th17 differentiation in PBMC. But I am wondering how to define the size of gene library, so...
31 July 2024 2,150 0 View
EDX analisys
31 July 2024 5,947 2 View
I am currently working on a project involving liposomes and need to determine the maximum volume of siRNA that can be added to a 2.5 mL liposome solution with a total lipid concentration of 10...
30 July 2024 6,420 1 View
I am working on algal extract to which gas chromatography (Not GC-MS) spectrum I want to discover. My question is can we identify specific compounds using retention time if I compared the RT with...
29 July 2024 8,034 4 View