Want to know suitable protocol to determine amino acids in animal feed and check the purity of commercial methionine
The most perfect method for the determination of the amino
acid composition of pure protein, feeds or biological fluids is still the
ion exchange column chromatography (IEC). By the help of the lithium
buffer system most of the problems on the field of free amino acid analysis
of biological fluids can be solved. At IEC most contaminants move
rapidly through the post-column system and are discarded before separation
of amino acids begins, resulting in better performance. The time of
the sample preparation is minimal compared to pre-column methods, and
the detection (with ninhydrin or OPA) is chemically specific for aminoacids. Nowadays a new off-line sample preparation method was introduced
before analysis by anion-exchange chromatography and integrated
amperometric detection, which eliminates carbohydrates from amino acid
samples. The major problems remained the hydrolysis of the protein, the
deproteinization of the biological fluids and the partial decomposition of
methionine, cysteine and tryptophan during the sample preparation for
analysis. At the moment the traditional IEC with postcolumn ninhydrin
derivatization seems to be the best for both pure proteins and feeds
and complex mixtures, but in some comparison the HPLC methods were
found to be similar to that of the IEC
common column
Whant to know ISO method or AOAC method as well as reference method given in Chinese Standard for DCP
01 February 2019 2,136 3 View
Other than European table of energy values for poultry feedstuffs,
06 July 2015 1,182 0 View
Range 50 to 400 and 50 to 800.
09 October 2013 1,149 1 View
I would like to learn more about SPSS and Its application especially in regards to data analysis. Please suggest me how I can learn more about it. Thank you so much.
11 August 2024 9,101 4 View
I have reverse sequences (AB1 format), can I base on reverse DNA sequences to perform nucleotide alignment, convert nucleotides to amino acids and deposit the sequence in GenBank database?
11 August 2024 5,138 1 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Willett, Shenoy et al. (2021) have developed a brain computer interface (BCI) that used neural signal collected from the hand area of the motor cortex (area M1) of a paralyzed patient. The...
10 August 2024 7,180 0 View
I'm currently exploring the application of Python in textile engineering, specifically in areas like data analysis, process automation, and the development of smart textiles. I'm interested in...
10 August 2024 7,429 2 View
How can I use the cif data obtained from rietveld refinement extracted via gsas2, for microstructural analysis using ETEX software?
09 August 2024 7,718 0 View
This larva was captured using a plankton net in the Persian Gulf during the summer. I believe it may be a Facetotecta nauplius.
08 August 2024 3,746 4 View
Let's say we have a standard, regular hexagonal honeycomb with a 3-arm primitive unit cell (something like the figure attached; the figure is only representative and not drawn to scale). The...
07 August 2024 1,937 1 View
A fungal strain was treated with nanoparticles. We want to do an environmental SEM analysis. So could anyone share your views on preparing the sample? Thank you.
07 August 2024 5,307 1 View
Hello What should be done to separate and identify organic acids in HPC when their RetTime is the same?Like oxalic acid with Propanoic Acid.or acids that have a very close RetTime.
07 August 2024 8,782 3 View