Can DLS measurement distinguis the hydrodynamic size of particles with 250nm and 270 nm? what is the resolution of the method?
No. If the 250 and 270 particles are mixed together you can't resolve them independently. It will be one broad peak. As a rule of thumb, DLS can't resolve nanoparticles whose sizes differ by less than a factor of three.
Is there any institutes in India where viscosity of a fluid can be studied under varying magnetic fields
05 February 2024 9,569 0 View
I want to study the viscosity of the of ferrofluids. Would anyone please suggest me institutes in India where I can do magneto rheology studies ?
10 January 2024 2,976 1 View
I have capped ironoxide nano particles with hydrophillic amino acids which show good stabilisation ( no sedimentation ) in neutra pH. How ever when the Zeta potential was measured, the value is ~...
22 June 2023 9,767 8 View
I want to do the SEM and TEM of Fe3O4 nanoparticles to confirm the particle shape and size
25 October 2022 9,440 7 View
i am looking for the time dependence of hummers method, how long should i proceed the reaction before quenching with h2o2
26 September 2021 8,355 2 View
I used eye tracking to examine how participants from two different populations (A and B) react to an image. Participants in population A exhibit larger pupil sizes over time, but they also have...
10 August 2024 3,229 0 View
I am using Rhodamine6G as gain medium and silver nanoparticles as scatterers on a microscope slide and laser input 532 nm comes from above.
09 August 2024 9,894 2 View
average particle size calculation from TEM
04 August 2024 2,921 1 View
TEP presentation caption (The Environmental Project) Re: Why should Washington’s DC, or any country government point of location think of as nowadays of as to being 'tomorrow as to come! if it...
03 August 2024 2,484 1 View
Dear Researchers I need to know, how to load and plot 2D-PIV (particle image velocimetry) recorded velocity vector field data in Tecplot? Thank You
02 August 2024 3,615 1 View
Hi everyone, Recently I have been conducting Dynamic Light scattering experiments in a micellar solution at 5 and gel at 37 degrees of Celsius with latex particles of diameter 190-500 nm. While...
01 August 2024 1,168 4 View
The delta function seems produce logical contradictions when analyzed on a fundamental level. I would be curious if anyone else agrees.
31 July 2024 10,109 3 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
I used Aqua regia to clean Au nanoparticles in the used glassware. But for some reasons, it is not heating up upon mixing. The color did change from no color to light orange. The Au NPs on the...
25 July 2024 4,390 0 View
What should be the zeta potential of bovine milk exosomes
25 July 2024 7,376 5 View