In ADXRD all the peaks are matching with theoretical pattern in peak positions. But one peak has intensity lower than the theoretical value. Others are matching as well. What may the reason behind this? May there be twinning? Or strain?
Dear Santanu,
you may share your diffractogram(s) and tell us what type of sample you are dealing with. So we could better draw conclusions.
Changes in relative intensity ratios also gives an idea about the changes in the atomic positions.
Most probably you have the texture effect- a part of related matter falls into less probable orientation .
I think such perfection you can't expect from powder XRD and it can be possible from single crystal XRD.
Gas loading (as pressure medium) in DAC requies cryogenic facility. What is the advantage of the gas loading compared to liquid?
10 November 2018 503 2 View
Before starting SCF cycle for calculating energy or band structure its necessary to optimize the parameters e.g., RKmax, K-mesh, Gmax in WIEN2k as well as any DFT code. Is there any script file...
08 September 2018 2,307 3 View
If in a lattice structure with lower symmetry, one atom is surrounded by atoms with different distances in the unit cell, what will be the the nearest neighbor distance and number of nearest...
06 July 2018 7,904 4 View
For any oxide material, is it possible that bulk modulus decreases,i.e., compressibility increases with increasing pressure? Is there any instance for that?
05 June 2018 5,012 3 View
For an oxide in orthorhombic structure, I can see 10 oxygen atoms are surrounding a metal atom, but the very atom is reported to be 7-coordinated. I can't understand how should I determine...
31 December 2017 9,645 3 View
I convert an XRD data to a .gsa extension file and use it as input/ histogram of GSAS. But can't understand the numbers in the file. May anybody let me know what do the numbers mean?
09 October 2017 4,923 0 View
I am refining a synchrotron XRD data of oxide ceramic using Rietveld method in GSAS. After refining cell, profile parameters chi2 is 1.2. If I refine the atomic positions now will they be...
08 September 2017 9,373 4 View
I use profile type 2 in GSAS for refinement of oxide ceramic material. Grain size and microstrain may be calculated from the profile parameters LX, LY respectively. I want to know how much...
08 September 2017 9,573 3 View
I am refining a material with 3-atom formula by rietveld refinement method using GSAS. I am attempting to refine the atomic position of the lightest atom at the very last and seeing that the x,y,z...
08 September 2017 9,156 3 View
Hi, I am after the reference below, my library says it cannot obtain a copy either locally or internationally, any help appreciated! Chris Wang ZM, Heshka S, Wielopolski L, Pi-Sunyer FX, Pierson...
03 March 2021 6,193 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
01 March 2021 1,290 2 View
When you observe the presence of Tyndall in an inflamed eye: Does each of the small floating dots correspond to an individual cell or to an aggregate of cells? Does a conventional slit lamp have...
27 February 2021 6,326 2 View
27 February 2021 2,753 4 View
I have tried every combination of parameter changes and after that i have a poor chi square value. I can't get it lower any further. I know there have been a lot of discussion about Rietveld...
26 February 2021 8,480 3 View
I am working on TiO2 composite material and the results of XRD have a lot of small/junk peaks and while I apply a smooth filter in Origin then the other characteristics peaks disappear so anyone...
26 February 2021 8,183 3 View
I had a crystal hit in a well with 0.1M HEPEs pH 7.5, 10%(w/v) PEG 4000, and 20%(w/v) isopropanol. Why is isopropanol in w/v here if it's just solvent? How do I recreate this well condition?
25 February 2021 9,761 1 View
i am trying to download x'pert high score software, but can't download it. please do suggest software for phase analysis
24 February 2021 5,687 4 View
I am refining my XRD data using in FullProf program. The intensity of the modulated X-ray peaks is almost flat. I tried to adjust the peak intensities but unsuccessful. What is the reason? I guess...
23 February 2021 2,304 4 View