The Start-Up Vent also called Start-Up Vent Line or Start-Up Vent Valve in a boiler plays a critical role during boiler start-up, shutdown, and low-load operations.
Start-up vent valve is generally manual, motorized or pneumatic operated. Now a days all Boilers have start up vent with motorized valve followed by pneumatic control valve.
Start-up vent line is always tapped from main steam out let line before or after safety valves and extended to suitable height. Start-up vent lines are equipped with silencers to reduce sound level of super heater steam upon venting. Steam carrying capacity of the line is 30-35% of Boiler MCR (Maximum continuous rating) or boiler capacity.
Generally, there is no flow meter for this line.
Functions of start-up vent control valve.
Main function: Start up vent is used to provide minimum flow to Boiler:
As like high pressure pumps, Boilers should have minimum steam flow from Boiler during start-ups or low load operation. And this is the main function of the start-up vent line.
This minimum steam flow from start-up vent is for ensuring sufficient cooling steam is flowing through super heater coils. If NO or less steam flows through the SH coils will lead to starvation of the coils during boiler start-ups, shut downs and no-load operations.
There fore operator should ensure the opening of start up vent valve during start ups & sudden steam cut off due to process disturbance or grid failure etc.
Other functions of start-up vent valve/line are;