What is the dielectric strength of highest practical vacuum in the range 10^-9 torr to 10^-12 torr, if the electrodes are smooth Pt (W=5.4 eV) ?
Hi Thomasz,
20...50 kV/mm and depends on the absolute pressure and electrode form. Maybe that helps: https://web.archive.org/web/20120301112907/http://www.htee.tu-bs.de/forschung/veroeffentlichungen/giere2002.pdf
regards
Erik
It would have to have transparent leads and deep sub-lambda geometries of photosensitive elements.
01 January 1970 2,330 1 View
If I put charge q onto an electrode, it will not be more than neutralized by the charge due to polarization of a ferroelectric. My email: [email protected]
01 January 1970 2,576 2 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
How do you tie-break and rank these two in their strength?
03 August 2024 4,471 1 View
Machine learning (ML) has shown great potential in predicting the compressive strength of concrete, an important property for structural engineering. However, its practical application comes with...
03 August 2024 2,546 2 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View