We are struggling to filter a GO solution. We have tried a number of different membrane materials, but filtration is extremely slow/not filtering at all.
Please read the GO sample preparation taken from "Graphene Oxide Thin Films: A Simple Profilometer for Film Thickness Measurement" published in International Journal of Engineering and Advanced Technology IJEAT)
ISSN: 2249 – 8958, Volume-2, Issue-3, February 2013
A. Sample preparation
For synthesis of GO we have selected well known method Hummers Method [8] from graphite flakes as described in our previous work [9]. Homogenous graphene oxide aqueous suspension with a concentration of 0.05grams of GO was suspended in 20ml Water of and 20ml of Ethylene Glycol in two different beakers. Then after the solutions sonicated by probe type sonicator for 2 hrs for uniform aqueous solution.2grams of PVP(Polyvinyl Pyrrolidone) was added to the aqueous solution and stirred at 800C for 5hours. The GO suspension was then spin coated at 6000 rpm for 30 s with a spin coating apparatus[10-14] (HOLMARC Spin
coater-model: HO-TH-05) on clean fluorine doped tin oxide (FTO), indium tin oxide (ITO) substrates and glass slides, which were first washed with acetone, ethanol and deionized water for 10 min successively under the assistance of ultrasonication. The GO thin films were obtained after drying at room temperature for 24 hrs as shown in Fig.1.
Please read the GO sample preparation taken from "Graphene Oxide Thin Films: A Simple Profilometer for Film Thickness Measurement" published in International Journal of Engineering and Advanced Technology IJEAT) (see attached file)
ISSN: 2249 – 8958, Volume-2, Issue-3, February 2013
A. Sample preparation
For synthesis of GO we have selected well known method Hummers Method [8] from graphite flakes as described in our previous work [9]. Homogenous graphene oxide aqueous suspension with a concentration of 0.05grams of GO was suspended in 20ml Water of and 20ml of Ethylene Glycol in two different beakers. Then after the solutions sonicated by probe type sonicator for 2 hrs for uniform aqueous solution.2grams of PVP(Polyvinyl Pyrrolidone) was added to the aqueous solution and stirred at 800C for 5hours. The GO suspension was then spin coated at 6000 rpm for 30 s with a spin coating apparatus[10-14] (HOLMARC Spin
coater-model: HO-TH-05) on clean fluorine doped tin oxide (FTO), indium tin oxide (ITO) substrates and glass slides, which were first washed with acetone, ethanol and deionized water for 10 min successively under the assistance of ultrasonication. The GO thin films were obtained after drying at room temperature for 24 hrs as shown in Fig.1.
Thanks for the reply Rafik, and for the attached paper. However, we are looking for filtration techniques in particular. Spin-coating is an option if filtration doesn't succeed.
Thanks for the reply Rafik, and for the attached paper. However, we are looking for filtration techniques in particular. Spin-coating is an option if filtration doesn't succeed.