I'm trying to simulate the tensile test of corroded tensile specimen and compare the results from the experiment which is already done.

I tried to extract the reaction force at the reference point(RF) 1 and the displacement at RF 2.

However, the displacement where the specimen yield doesn't match the experimental data at all (In fact, the specimen yields at about 2 mm but from the simulation it yields at 0.1mm? ).

I gave velocity to RF 2 just the same as the experiment. Any advice?

More Youngjun Nam's questions See All
Similar questions and discussions