I have mostly come across the usage of humidifiers but are there some alternatives, if we want to vary RH of air ?
You can try following method:
Humidity controlled chamber was designed in our
laboratory using transparent glass, inside which
hygrometer and humidifier/dehumidifier dish were placed. Saturated aqueous solution of K2SO4 was used as
humidifier for increasing the %RH from 10 to 90 whereas
saturated aqueous solution of KOH was used as
dehumidifier to decrease the humidity inside the chamber
from 90 to 10 %RH. You can purchase hygrometer with thermometer only, which is very low cost.
Shakti Singh Thank you for you reply! Really appreciate your input. I will definitely try it!! I'm still reading the pdf so will come back to you if I have some questions regarding same.
Can organic farming be made sustainable in terms of economics for longer run? Keeping population- demand and supply chain in mind? Can it be affordable and reach out to wider community? Can...
29 March 2020 3,043 14 View
GFP is encoded in bacterial cell, which filter is required to observe such cells under a fluorescence microscope?
21 January 2020 2,561 3 View
07 September 2016 623 5 View
I synthesized water-soluble upconversion nanoparticles coated with PEI using polyol method. Morphology was good and now I want to check the emission of my particles and PL is not available. Can I...
25 October 2015 7,320 14 View
How to prepare a buffer of NH3-NH4Cl with pH 10 for a titration between Zn2+ and EDTA?
18 December 2012 9,822 9 View
Hello, I have a mechanism where air rises due to convective flows. In this simulation, nothing is driving the air except this. I understand that the Boussinesq approximation only works for small...
02 March 2021 4,910 3 View
I am trying to obtain the response and recovery times for my gas sensor device. It appears the the response/recovery times are primarily dependant on the flow rate of the gas I inject into the...
26 February 2021 1,511 3 View
Dear All, We are using Autodesk cfd to calculate the air flow in a single sided naturally ventilated room, where air flow depends only on buoyancy due to temperature difference between inside and...
25 February 2021 9,602 4 View
Due to the unavailability of climate rooms, I want to carry out an experiment that require the use of certain saturated salt solutions especially those that can condition the wood specimen to 35%,...
25 February 2021 8,139 1 View
As it is highly probable that pellets will have a higher degree of air gaps and voids than thin films, is it possible to pole the samples with corona poling nevertheless? Or is there the...
24 February 2021 1,349 1 View
Dear all, My research group is currently working with a 12-litre fermenter. Somehow, if we do the fermentation for more than 20 hours, the process will be more prone to contamination. Our current...
23 February 2021 1,908 2 View
Hello, I created a very tall tower (>1000m) and applied pressure boundary conditions at the inlet (bottom) and outlet (top) that correspond to the pressure are their relative altitudes....
22 February 2021 9,972 4 View
Dear Research Gaters, Let me first add context to the question. I am looking to simulate the waste management system and resources of a city. The hardware devices I need to simulate include,...
21 February 2021 2,333 4 View
My team is designing a dual channel microfluidic chip that runs air and water. I think we've decided on the NE1000 syringe pump for it's versatility and feedback control. We will be ordering the...
18 February 2021 9,928 2 View
I am working on cathode material. I have made different Li-ion coin cell against Li metal using commercial available cathode materials such as LCO,LMO, LFP and NMC and also with the lab...
18 February 2021 1,450 3 View