It is a simulation of an underwater pipeline, where there is a low concentration of oxygen, and I try to follow cathodic delamination of epoxy coated steel with thickness 700 micrometer.
We begin a new research related to MOF (powder) and we need to predict its molecular structure. We have powder-XRD and atomic ratio from EDX and XRF, but we do not have Single Crystal-XRD...
10 November 2018 6,607 5 View
What are the differences between ECN and ZRA techniques for corrosion measurement?
01 January 1970 5,161 4 View
The metal is pipeline steel (X70) and the coating matrix is epoxy. I need to follow the delamination during applied cathodic potential. The solution is NS4.
01 January 1970 1,531 7 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello everyone. Given microstructure image belongs to a 12% ledeburitic cold work tool steel (annealed and tempered). The sample was etched with picral (100 mL ethanol and 4 g picric acid). I...
02 March 2021 4,119 3 View
It is oftentimes said to be a distinctive metallographic trait that differentiates a fully austenitic and a fully felly ferritic steel without etching that might distinguish between two. Why...
02 March 2021 728 2 View
Is the electropolymerisation of polyaniline coating over stainless steel (SS) via Cyclic voltammetry technique is really adherant? Else how to improve the adhesion of the coating, whether any...
01 March 2021 8,220 2 View
As I was tweaking step-by-step OpenCalphad6 Macros step1.ocm involving phase and thermal property calculation of a High-speed steel, I could not incorporate more than 6 elements in the steel...
01 March 2021 8,840 1 View
I have a structure that employs d-ring swiveling tie-downs that corrode during use and become "frozen". I have sample swivel assemblies that I wish to corrode to see if I can free them using one...
01 March 2021 3,739 3 View
Is DCFDA appropriate for measuring total ROS production, or can it only detect certain types of ROS? If I want to measure total ROS production, which dye should I use?
01 March 2021 9,447 3 View
I am aiming to determine the ADC values of a commercial fish feed, but I do not have a steam pelleter or extruder available to me. Ideally, the pellets could be coated with some inert marker....
28 February 2021 7,967 3 View
Do we immerse the bricks horizontally or vertically ? #bricks#waterproofingsurface#civil#engeenering#chemicalengineering#wax#parafinwax
28 February 2021 6,685 2 View
I want to use 0.1% gelatin. Should that be made in PBS or sterile water? Should I autoclave the gelatin soln after making it in water/PBS?
28 February 2021 274 2 View