Dear friends ;
I did a stiffness test on a E-glass/Epoxy composite pipe which the pipe exposed to transverse vertical load . The Force-Displacement diagram is like attached file ? Why ?
pipe diameter = 100 mm
t=3 mm
thanks
Hi friends i'm working on progressive damage of Glass/Epoxy composite pipes. Because of plane stress condition, I use Abaqus default damage criterion (Hashin). The problem geometry is the...
07 August 2019 7,562 12 View
Dear friends. I modeled a graphite- epoxy composite plate with stacking sequences of ( 0/45/-45/0) in Abaqus software. but when i want to see failure indexes of Tsai-wu failure theory for each...
08 September 2018 3,012 3 View
Hi friends. I built the microstructure model of dimensions (50 micrometer * 50 micrometer ) and when i meshed it, i could not large zoom on model in detail. Can anyone help me ? Additionally ,...
08 September 2018 5,872 3 View
Dear researchers. I've modeled an Eglass/Epoxy composite plate containing a hole in the center and is tensile-loaded from both sides. Hashin progressive failure in Abaqus software is used to see...
08 September 2018 2,027 4 View
08 September 2017 9,457 3 View
08 September 2017 1,826 1 View
Progressive Damage modelling??
07 August 2017 5,779 4 View
03 April 2017 3,511 2 View
Hi, I am using GROMACS 5.1.4 to simulate water in contact with a surface. I am only interested to calculate some properties of water near the surface. Let's say at a distance of x nm from the...
03 March 2021 9,989 2 View
I have prepared a manuscript in IEEE Latex template, but for some purpose, I need to prepare a word file as well (detailed format is not required). Compared to two column .tex file, one column...
02 March 2021 1,830 3 View
Hello, I am working on a soil project and I found a primary research article that tests how the modification of agricultural soil can cause global warming, using a thermal collector, however I...
02 March 2021 7,161 3 View
I made a vertical section plot with WOA .nc file on ODV, and now I want to plot my stations (csv. file) in it. Does anyone know how to import my points to the section? They are two different...
01 March 2021 3,610 1 View
01 March 2021 1,290 2 View
I've used the "export data" option in Vesta software to convert my unit cell into a cif file however when I use that cif in atomsk it shows error such as "can't read the position of atom 0". If I...
28 February 2021 4,966 3 View
Hi, all! How can we use a hybrid element in Abaqus Dynamic/Explicit for impressible materials? I have not find the choice for explicit element in Abaqus CAE. I am wondering whether it is possible...
25 February 2021 9,936 2 View
25 February 2021 5,713 1 View
Hi I am very new to proteomics analysis. I have got raw files from core facility running thermofisher TMT 16plex 4 hours. I cannot find on maxquant the option TMT16Plex there is only up to 11...
25 February 2021 1,675 3 View
I have a pipe with 10 mm in Diameter and 2 bar pressure, the fluid velocity is 200 m/s, the fluid is air. is there a way to reduce velocity without affecting the pressure value?
25 February 2021 7,187 3 View