The Energy plus documentation (input/output) specifies that for typical commercial buildings in the USA, a reasonable default value for ground temperature: building surface is 2 degC less than the average indoor space temperature. And a practician in 2011 mentions that he has seen many simulations doing simplified method:

- using the last month's mean temperature, less 1 degree.

( http://energy-models.com/forum/ground-temperature-building-surface )

Similar to the Energy+ O/I documentation and Aside from applying:

  • Auxiliary programs that can be simulated independent of the IDF file and determine detailed ground heat exchange ------ Ground heat transfer modeling " with "kiva"
  • Ground Temperature Calculation through a Basement\slab Calibration process.

- What is the best and easiest (more abstract) method, to input reasonable default values as a ground monthly temperature for small/large residential building models?

More Adel Boumerzoug's questions See All
Similar questions and discussions