Hello.
I am working on a micro scale simulation of evaporation inside a porous structure, using ANSYS FLUENT. It is a transient two phase model(VOF) considering water and vapor inside a micro scale pore. I am using UDF codes to apply the source terms relative to the mass transfer according to Schrage's model formulation.
The results that I get seem to be logical, but my problem is that the time steps that I have to use are very small ( in the order of ~1e-9 s), which make it impossible to reach convergence.
Every time I increase the time step, I face the error that the "Global Courant number is greater than 250.00. The velocity field is diverging. check the solution and reduce the time step".
I really appreciate it if you have any suggestions or solutions for this problem or you have any recommendations for me to increase the time steps to more realistic values.