I'm looking for high temperature (~750 C) die attach epoxy/resin which is thermally conductive and electrically insulator.
Example: Temperature sensor epoxy/resin coating. The image is attached for reference (Source: www.google.com).
Be precise with temperature requirement: K, C or F?
Thank you for bringing it to my notice, it's in Celcius.
~750 C
You must think of high nickel base alloy or conductive ceramic cover for the temperature measuring sensor for 750 C. There is no epoxy coating to withstand such a high temperature.
Hi, I am looking to work with the NAO humanoid robot in my Masters thesis and looking for various application areas and incorporating state-of-the-art technologies for solving a problem. Your...
04 August 2019 982 4 View
I am trying to get output of laser beam from a FOC laser beam with diameter ranging from 100 microns to 1000 microns. The FOC diameter is 200 micron and NA is 0.22. What kind of lens or...
02 July 2019 6,055 3 View
I am trying to make a force amplification from the lead metal. The pressure applied is more than the yield of the lead (14 MPa) which is around 150 MPa. Is it possible that the lead will behave...
02 July 2019 1,554 0 View
I need some quality literature on the factors affecting the backscatter method. Particularly when it is used to determine the wet density of the compacted fills containing materials other than the...
15 February 2018 2,915 4 View
Hi, I want to conduct an accelerated shelf life testing of packaged coconut water. What can be the possible acceleration factor for the same.
22 February 2017 3,760 5 View
Is there a link/ forum to see high impact articles on prophylactic vaccine research/ latest technologies in vaccine research? I am screening potent adjuvants to generate a Th1 biased response,...
13 March 2016 6,941 2 View
I am testing a new antigen and do not have purified antibody (IgG subtypes or IgA) to generate a standard curve. What's the best way to represent the titers: having OD values adjusted for dilution...
06 December 2015 2,557 4 View
If possible, I'd love some references!
08 April 2014 2,359 0 View
I am developing a CNN model to recognize 24 hand-signs of American Sign Language. I have 2500 Images/hand-sign. The data split is: Training: 1250 Images/hand-sign Validation: 625...
01 January 1970 1,376 3 View
Can anyone explain this method? Especially the last statement where it says only at 1.5 to 2.5mins was the MS/MS connected to the UPLC. How is that possible, is it a feature in this specific...
11 August 2024 8,141 3 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
I did PR spin coating on trench structure. I used AZ P4620 PR and the thickness or PR is around 11um. The substrate is Si. And my trench structure depth is 141um(negative way). Even though I...
08 August 2024 2,298 0 View
My name is Apurva Saoji. I am a Ph.D scholar in Computer engineering in India. I am looking for international expert in reviewing my PhD thesis, "Competitive Optimization Techniques to Minimize...
07 August 2024 4,600 2 View
Hello What should be done to separate and identify organic acids in HPC when their RetTime is the same?Like oxalic acid with Propanoic Acid.or acids that have a very close RetTime.
07 August 2024 8,782 3 View
I have been getting a low plasma and no coating while doing rf sputtering of copper doped ZnS using a power of 140 watts and at pressure of 6.5x10-3 Mb.
07 August 2024 4,526 4 View
Hi! So i attempted to understand a novel protein behavior towards heat application by analyzing its secondary structure change. I subjected the protein to a thermal denaturation analysis using...
06 August 2024 1,989 3 View
I am planning to collect human fecal samples for metatranscriptomic analysis using MGI. These samples are from indigenous people living in a region with high temperatures. I will have access to a...
06 August 2024 1,367 3 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
A typical reforming section in a large-scale Haber-Bosch process (Figure 1) comprises two reactors. A mixture of methane (CH4) and steam (H2O) is fed into a primary reformer to produce syngas via...
01 August 2024 7,051 5 View