I want to perform baseline correction for a raman data.
Which kind of baseline correction is the best for Raman?
I am using origin. Should I pick up the random baseline points and subtract it or i take an exponential fitted line of these points?
# crystallite is the part of the crystal which coherently diffracts the X-rays falling on them. # A ferroelectric domain is the part of the material in which all the polarization vectors are...
03 April 2019 7,759 9 View
# Barium Titanate (BT) is tetragonal at room temperature. # XRD, Raman and numerous other studies show that BT becomes cubic when Zirconium or tin is substituted at titanium site minimum by 20%. #...
11 December 2018 662 3 View
What does it mean by the softening of a phonon mode? In the available literature i have interpreted two definitions - # 1. Softening of a mode means the phonon peak becomes smaller and broader. #...
10 November 2018 5,059 2 View
# Band gap of ZnO is 3.37eV which corresponds to an emission of 378nm. # Co-doped ZnO nano rods give an emission at 330nm. # This is not a confinement effect as the average diameter of the rods is...
04 May 2017 8,319 7 View
In fact, i want to know that before and after the permittivity peak(curie temp.) permittivity Vs time curve shows very low permittivity as compared to the peak value both before and after curie...
02 March 2017 9,431 2 View
I am preparing Ni doped BT by sol-gel method. i dissolved Ni nitrate and barium acetate in acetic acid. in case of small quantity of Nickel nitrate it is dissolving properly but in case of high...
02 March 2017 2,956 3 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
The first pdf file I uploaded had an error. So I uploaded an updated, corrected pdf of that paper with a different pdf name. I dpon't want the old copy to be download or read.
07 August 2024 9,508 1 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
I'm trying to calculate the tolerance factors of the hydride perovskite and the value calculated by me and the reported values are contradictory. Need more clarity in using the correct ionic radii...
01 August 2024 2,614 1 View
Following curve related to Co0.6Mn0.4Fe2O4 Magnetic nanoparticles with extra phase a-Fe2O3. I will appreciate to help me to interpretation this spectroscopy, especially the blue line.
31 July 2024 9,140 2 View
How to change the displayed full article text to its corrected version? In the file on the page of the journal where I published the article, there was an error in the text, the table is...
30 July 2024 3,229 2 View
I'm using a InVia Renishaw Raman microscope system (785nm wavelength, 600l/mm grating density) to acquire Raman images on human brain samples, at 50um resolution. The samples are placed on MgF2...
30 July 2024 8,771 3 View
The entropy measured of molecular graphs plays a crucial rule. The network structures in some cases are very lengthy calculations to handle. Some author avoid to construct table where as most...
30 July 2024 3,126 0 View
Hello everyone, I am new to this characterization but watching videos on youtube I have already plotted a Nyquist plot (Z' and -Z'') and already fitted models on my material using Zsim. But now I...
29 July 2024 1,376 0 View
Dear all, I have noticed, as the ZnO content increases, the Raman intensity at 100cm-1 also increases. However, there is a peak nearby at 130 cm-1, which I could not find in any paper related to...