I want to determine the oxygen vacancy in Perovskite with Raman spectroscopy. Is there any possibility? And in which condition it would be possible?
Take help from attached article but better to do XPS.
Thank you.
How can I get clear explanation about this (Γ = A1g + A2g + B1g + B2g + Eg + A2u+2B1u+3Eu)?
Read any book on Raman spectroscopy ,
I am attaching one for you.
Is it possible to increase the intensity of UV-vis absorption in the interaction of the groove connection mode?
29 June 2024 4,867 4 View
i was determined ammonia nitrogen by phenol hypocholorite method, now i have some data like wieght of sample and absorption level at 630 nm and standard curve and standard equation obtained from...
15 May 2024 2,096 2 View
Is it possible to use sodium polyphosphate instead of sodium hexametaphosphate to measure soil texture? How and in what concentration?
06 April 2024 5,805 5 View
I have done the docking process using Schrödinger for several ligand-proteins, how to calculate the value of ΔG for each of the ligand-proteins? regards
19 February 2024 5,869 3 View
Is it possible for the solution of the Fokker-Planck equation to have negative values? I am referring to the mathematical aspect, irrespective of its physical interpretation. Additionally,...
25 December 2023 560 3 View
Hi everyone I synthesized carbon dot with folic acid and citric acid with DMF solvent. After analyzing, it was found that there is no problem with the synthesis. But using a fluorescent...
23 December 2023 4,111 3 View
After reviewing the latest srsRAN documentation, I understand that handovers are facilitated by modifying RR configuration files. I am curious if it's feasible to implement handover scenarios by...
07 November 2023 3,959 2 View
In my research, I have four classes of students, and these classes have been divided into four groups. The students in these groups are pursuing their studies in four different academic...
27 October 2023 8,335 3 View
Dear Colleagues I would greatly appreciate it if one of my esteemed colleagues in the field of English language education could assist in native-like reviewing, editing and revising a research...
15 October 2023 9,043 3 View
Can bioprinted-scaffold extract be used indirectly for live/dead (AO/PI) cell staining like the indirect MTT? Thank You
25 August 2023 7,103 0 View
Greetings When one is to perform Simulation or modelling of Pyrolysis of Biomass Waste materials using Aspen Plus software, and one has both the macromolecules breakdown (Cellulose, Lignin and...
06 August 2024 5,023 1 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
Hello. I am working on ROS production of two systems: system A is cerium oxide and hydrogen peroxide, system B is cerium oxide nanoparticle, hydrogen peroxide and potassium bromide. I did some...
04 August 2024 5,974 3 View
Why BaO (s) + H2O(l) ---> Ba 2+(aq) + 2 OH - (aq) if Oxygen loves owning all the electrons, why would it bind to hydrogen which competes with Oxygen for electron ownership more so than...
03 August 2024 5,392 1 View
I heard an explanation about something being a better proton acceptor or lone pair donor but that doesn't make sense. I couldn't explain in in terms of acid-base theory. The hand-waving way I saw...
03 August 2024 9,918 0 View
I'm trying to calculate the tolerance factors of the hydride perovskite and the value calculated by me and the reported values are contradictory. Need more clarity in using the correct ionic radii...
01 August 2024 2,614 1 View
Following curve related to Co0.6Mn0.4Fe2O4 Magnetic nanoparticles with extra phase a-Fe2O3. I will appreciate to help me to interpretation this spectroscopy, especially the blue line.
31 July 2024 9,140 2 View
Dear all! Oxygen vacancies do raise negatively the Fermi level by increasing the negative charge in the semiconductor crystal structure. In the case of n-type semiconductors, I wonder if this...
30 July 2024 8,339 2 View
I'm using a InVia Renishaw Raman microscope system (785nm wavelength, 600l/mm grating density) to acquire Raman images on human brain samples, at 50um resolution. The samples are placed on MgF2...
30 July 2024 8,771 3 View
Hello everyone, I am new to this characterization but watching videos on youtube I have already plotted a Nyquist plot (Z' and -Z'') and already fitted models on my material using Zsim. But now I...
29 July 2024 1,376 0 View