I have colored the molecule with b-factor and I don't want any lighting or shadows to influence this coloring.
Dear Bose
In order to escape lighting and shadows, usually use white color in the background. Go to graphisc-> Colour, Categories-> Display, Names-> Background, Colors-> white. Then it should be ok.
Background is already white; doesn't help at all.
The best solution I have found till now is to turn off all the 4 lights, and in ray tracing options, use AO ambient = AO direct = 1.0.
Is there a better way?
I wonder how can a Physicist work with live animals as a PI without collaborating with biologists.
06 July 2018 7,924 8 View
The electrodes are used for voltage measurement in the Brain and needs to be connected to pre-amplifiers. Is there any company or research group that can fabricate transparent microchip for this...
09 October 2017 2,105 8 View
I have different samples with height in the range of about 1.5 to 3 nm; as measured by ScanAsyst mode in air, with same AFM probe and same imaging force. I know that height measured by tapping...
31 December 2016 2,190 5 View
I am trying to estimate the width of DNA from its crystal structure.
08 September 2014 9,897 6 View
For force spectroscopy experiments with AFM, it is needed to calibrate the deflection sensitivity and spring constant of the cantilever. First I determine the deflection sensitivity very...
04 May 2014 4,770 17 View
I am imaging DNA using AFM. I extracted the gray scale intensity values from the image into a matrix of integer elements. Then I wrote a code in C++ to count pixels falling within a certain...
02 March 2014 5,079 28 View
Other than the usual method of adding divalent cations of small ionic radii, is there any better method? I want very clean background.
10 November 2013 7,014 0 View
Are the isolation tables using nitrogen or compressed air supply the best? What do you think about the active isolation platforms available from Herzan and Accurion that runs simply on electricity?
09 October 2013 4,461 13 View
Two special cases: 1. Both the promoter & terminator sequence is present. 2. Only the promoter sequence is present.
01 January 1970 6,670 3 View
I used eye tracking to examine how participants from two different populations (A and B) react to an image. Participants in population A exhibit larger pupil sizes over time, but they also have...
10 August 2024 3,229 0 View
Hi, I know that low molecular weight (MW) molecules generally tend to have higher mobility, while high molecular weight molecules tend to have lower mobility. However, in my experimental...
06 August 2024 1,495 2 View
kindly reply me. Thanking you in advance.
05 August 2024 7,727 4 View
I have protein-membrane simulations (PDB, PSF, DCD) and have noticed that water molecules near the protein are not visible in the simulations. How can I fix this issue? Is there a way to place the...
04 August 2024 1,200 2 View
Is it possible to conduct a molecular dynamics simulation to see the effects of a specific carbohydrate on the structure of lipids (e.g., micelle structure)? I am a beginner in this field and plan...
03 August 2024 3,371 3 View
I am using a windows system, what software I should use for hydration shell analysis with molecular dynamics?
02 August 2024 3,143 4 View
Molecular docking software/ websites?
02 August 2024 8,704 7 View
Hi everyone, Recently I have been conducting Dynamic Light scattering experiments in a micellar solution at 5 and gel at 37 degrees of Celsius with latex particles of diameter 190-500 nm. While...
01 August 2024 1,168 4 View
Dear all, I am working on particle deposition in human's & rat's respiratory airways using CFD and I am looking for the 3D CAD file for my simulations (STEP or IGES format). If somone has such...
29 July 2024 1,092 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View