I'm trying work in super-capacitors and for a redox system I am unable to get a get equal anodic and cathodic peaks. How should I proceed?
Dear Brahmari Honnappa
What redox system are taking for experiments?
If you take 1:1 molar ratio of both redox couple (mix) (like: 10 mM of Fe3+ and 10 mM of Fe2+), you will get almost equal peak in the cyclic voltammetry.
Best wishes,
Bapi
thank you for the answer
There are several answers on how to calibrate Ag/AgCl reference electrode, is it similar to the calibration of Ag/AgCl or is there any other way to calibrate the reference electrode.
10 March 2022 7,657 1 View
I know how to optimize the structure in gas phase using B3LYP model but i need to know what is the command used to obtain the optimized structure in particular solvent
17 April 2018 6,145 2 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
Do these peaks in the curve indicate primer dimer or non-specific products?
01 August 2024 7,466 0 View
Hi everyone, I'd like to better separate two close peaks coming from a bioconversion sample, I'm currently using a C18 KromaPhase 4,6mm Ø.I. SCHARLAU, particle size (µm): 10, pore size (Å): 100,...
30 July 2024 435 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...