I am looking to simulate the injection molding process for tensile specimens of a novel PHA. The simulation requires elastic modulus and shear modulus as parameters which I don't believe can be measured without performing a tensile test. The issue is that other parameters in the injection molding process can affect the strength properties of the material.
Would the only way to handle this be to optimize the process with an assumed value for these properties, mold and test the specimens, and iterate with the new values to optimize the process? Or is there possibly a better way to handle this?